Suppr超能文献

Permeability of medical gloves to mono- and dimethacrylate monomers in dental restorative materials.

作者信息

Lönnroth Emma-Christin, Ruyter I Eystein

机构信息

Department of Human Work Science, Luleå University of Technology, Luleå, Sweden.

出版信息

Int J Occup Saf Ergon. 2002;8(4):497-509. doi: 10.1080/10803548.2002.11076540.

Abstract

Dental personnel manually handle methacrylate-based restorative materials, which can cause skin irritation and allergies. The protection given by different types of medical gloves is not well known. Breakthrough time (BTT, min) was used as a measure of protection according to a European standard, using 2 test mixtures consisting of respectively 3 and 5 monomers. Fourteen gloves representing natural rubber latex, synthetic rubber, and synthetic polymeric material were tested. The BTT ranged from some minutes to more than 2 hrs for the 4 monomers with a molecular mass less than 300. The longest protection was recorded for Nitra Touch (nitrile rubber), Tactylon (synthetic rubber), and Metin (PVC).