Wang Fengjun, Zhao Yun, Wang Pei
Institute of Burn Research, Southwest Hospital, Third Military Medical University, Chongqing, 400038, China.
J Chromatogr Sci. 2003 Mar;41(3):142-4. doi: 10.1093/chromsci/41.3.142.
An isocratic high-performance liquid chromatographic method is developed for the determination of phospholipids in biological samples using a muPorasil silica column and a mobile phase of acetonitrile-methanol-85% phosphoric acid (90:3:1, v/v/v) at a flow rate of 0.80 mL/min. The effluent is monitored by a UV detector at 203 nm. With the method reported in this paper, phosphatidylinostol, phosphatidylserine, phosphatidylethnolamine, and phosphatidylcholine in biological samples are separated and detected successfully. The method is simple, rapid, and has excellent precision.