The decimal visual acuity chart is not easy to use for statistical analysis and requires a transformation into LogMAR units (decimal logarithm of the Minimum Angle Resolution). In contrast to the decimal chart, the logarithmic chart has an arithmetic progression and a constant interval between lines. The LogMAR chart makes statistical analysis of visual acuity easy. Change in visual acuity is calculated directly by subtracting LogMAR data, while the average visual acuity is obtained with the arithmetic mean value of the LogMAR data. The mean acuity expressed in LogMAR units can be transformed into a decimal chart for a more comprehensive result. To calculate the average visual acuity directly from the decimal data, the geometric mean value must be used instead of the arithmetic mean value.
小数视力表不易用于统计分析,需要转换为LogMAR单位(最小分辨角的小数对数)。与小数视力表不同,对数视力表具有算术级数且各行之间间隔恒定。LogMAR视力表便于进行视力的统计分析。视力变化可通过直接减去LogMAR数据来计算,而平均视力则通过LogMAR数据的算术平均值获得。以LogMAR单位表示的平均视力可转换为小数视力表以获得更全面的结果。要直接从小数数据计算平均视力,必须使用几何平均值而非算术平均值。