Intensity-modulated radiation therapy (IMRT) represents one of the most significant technical advances in radiation therapy since the advent of the medical linear accelerator. It allows the clinical implementation of highly conformal nonconvex dose distributions. This complex but promising treatment modality is rapidly proliferating in both academic and community practice settings. However, these advances do not come without a risk. IMRT is not just an add-on to the current radiation therapy process; it represents a new paradigm that requires the knowledge of multimodality imaging, setup uncertainties and internal organ motion, tumor control probabilities, normal tissue complication probabilities, three-dimensional (3-D) dose calculation and optimization, and dynamic beam delivery of nonuniform beam intensities. Therefore, the purpose of this report is to guide and assist the clinical medical physicist in developing and implementing a viable and safe IMRT program. The scope of the IMRT program is quite broad, encompassing multileaf-collimator-based IMRT delivery systems, goal-based inverse treatment planning, and clinical implementation of IMRT with patient-specific quality assurance. This report, while not prescribing specific procedures, provides the framework and guidance to allow clinical radiation oncology physicists to make judicious decisions in implementing a safe and efficient IMRT program in their clinics.
调强放射治疗(IMRT)是自医用直线加速器问世以来放射治疗领域最重要的技术进步之一。它使高度适形的非凸形剂量分布在临床上得以实现。这种复杂但前景广阔的治疗方式正在学术和社区实践环境中迅速普及。然而,这些进步并非没有风险。IMRT不仅仅是在当前放射治疗过程中增加的一项技术;它代表了一种新的模式,需要多模态成像、摆位不确定性和内部器官运动、肿瘤控制概率、正常组织并发症概率、三维(3-D)剂量计算与优化以及非均匀射束强度的动态射束投送等方面的知识。因此,本报告的目的是指导和协助临床医学物理学家制定和实施可行且安全的IMRT计划。IMRT计划的范围相当广泛,涵盖基于多叶准直器的IMRT投送系统、基于目标的逆向治疗计划以及具有患者特异性质量保证的IMRT临床实施。本报告虽未规定具体程序,但提供了框架和指导,以使临床放射肿瘤学物理学家能够在其诊所实施安全有效的IMRT计划时做出明智的决策。