Naidong Weng, Hua Sun, Roets Eugène, Hoogmartens Jos
Laboratorium voor Farmaceutische Chemie en Analyse van Geneesmiddelen, Faculteit Farmaceutische Wetenschappen, Katholieke Universiteit Leuven, Van Evenstraat 4, B-3000 Leuven, Belgium.
J Pharm Biomed Anal. 2003 Sep 15;33(1):85-93. doi: 10.1016/s0731-7085(03)00153-5.
Methods using TLC densitometry with fluorescence detection are described for the assay and purity control of tetracycline (TC), chlortetracycline (CTC), and oxytetracycline (OTC) in animal feeds and premixes. With a silica gel layer previously sprayed with 10% (m/v) sodium EDTA solution adjusted to pH 8.0 or 9.0, all the major impurities were separated from the main components and from each other. The mobile phase consisted of dichloromethane, methanol, and water. After development, the plate was dipped in a 30% (v/v) solution of liquid paraffin in hexane. Quantitation was realized by fluorescence densitometry at 400 nm. The limit of quantitation (LOQ) for tetracycline impurities is 0.8 microg/g, corresponding to 0.2% of the label claimed tetracycline (400 microg/g). The LOQ for impurities of tetracycline and chlortetracycline in premixes is 0.2% of the label-claimed TC (40 mg/g) and CTC (200 or 400 mg/g). The LOQ for impurities of oxytetracycline in a premix is 0.1% of the label claimed OTC (100 mg/g).
描述了采用带荧光检测的薄层色谱密度测定法对动物饲料和预混料中的四环素(TC)、金霉素(CTC)和土霉素(OTC)进行含量测定和纯度控制的方法。使用预先喷有pH值调至8.0或9.0的10%(m/v)乙二胺四乙酸钠溶液的硅胶层,可将所有主要杂质与主要成分相互分离。流动相由二氯甲烷、甲醇和水组成。展开后,将薄板浸入正己烷中30%(v/v)的液体石蜡溶液中。通过在400nm处进行荧光密度测定实现定量。四环素杂质的定量限(LOQ)为0.8μg/g,相当于所宣称的四环素含量(400μg/g)的0.2%。预混料中四环素和金霉素杂质的LOQ为所宣称的TC(40mg/g)和CTC(200或400mg/g)含量的0.2%。预混料中土霉素杂质的LOQ为所宣称的OTC(100mg/g)含量的0.1%。