Plomer M, Guilbault G G, Hock B
Department of Botany, Technische Universität München at Weihenstephan, Freising, Germany.
Enzyme Microb Technol. 1992 Mar;14(3):230-5. doi: 10.1016/0141-0229(92)90071-u.
A piezoelectric crystal immunosensor has been developed for the detection of enterobacteria in drinking water using antibodies against the enterobacterial common antigen. Applying an anti-enterobacterial antibody layer via protein A immobilization onto a 10-MHz crystal, a response is observed for 10(6) to 10(9) cells ml-1 of Escherichia coli K12, and for various other antigens of the Enterobacteriaceae family.
已开发出一种压电晶体免疫传感器,用于使用抗肠杆菌共同抗原的抗体检测饮用水中的肠杆菌。通过蛋白A固定化将抗肠杆菌抗体层应用于10兆赫的晶体上,可观察到对每毫升10⁶至10⁹个细胞的大肠杆菌K12以及肠杆菌科的各种其他抗原产生响应。