Suppr超能文献

荧光抗体染色在狂犬病诊断中的应用

THE USE OF FLUORESCENT ANTIBODY STAINING IN THE DIAGNOSIS OF RABIES.

作者信息

BEAUREGARD M, BOULANGER P, WEBSTER W A

出版信息

Can J Comp Med Vet Sci. 1965 Jun;29(6):141-7.

Abstract

Brain material from 750 domestic and wild animals submitted to this laboratory for rabies diagnosis was studied by the following three methods: a) microscopic examination of Williams' stained impressions, b) mouse inoculation test, and c) microscopic examination of impressions stained with fluorescein-tagged antibodies. The purpose of this investigation was to compare the sensitivity of the fluorescent antibody technique with that of two classical methods, when applied to the routine diagnosis of rabies. From the results obtained by one or the other method of study, 175 specimens were diagnosed as positive. Of these, only 58 (33 per cent) were detected by the examination of Williams' stained impressions. On the other hand, two rabid cases were missed by the mouse inoculation test, and four by the fluorescent antibody technique. Without being completely reliable, the last two methods proved to be almost equally sensitive and much more so than the examination of Williams' stained impressions.

摘要

本实验室接收了750份用于狂犬病诊断的家畜和野生动物的脑组织样本,采用以下三种方法进行研究:a) 对威廉姆斯染色印片进行显微镜检查;b) 小鼠接种试验;c) 对荧光素标记抗体染色的印片进行显微镜检查。本研究的目的是比较荧光抗体技术与两种传统方法在狂犬病常规诊断中的敏感性。通过一种或另一种研究方法获得的结果显示,175份标本被诊断为阳性。其中,通过对威廉姆斯染色印片的检查仅检测出58份(33%)。另一方面,小鼠接种试验漏诊了2例狂犬病病例,荧光抗体技术漏诊了4例。后两种方法虽然并非完全可靠,但事实证明它们的敏感性几乎相同,且比检查威廉姆斯染色印片的敏感性要高得多。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/2b84/1494414/4ebd92221c9f/vetsci00031-0008-a.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验