Abstract

We evaluated an automated immature granulocyte (IG) count in the peripheral blood with the XE-IG Master (Sysmex Corporation). The XE-IG Master is the upgraded software package for the XE-2100 automated hematology analyzer. Reproducibility tests demonstrated a mean coefficient of variation of 7.02% for the IG percentage (IG%) and 6.93% for the absolute IG count. Correlations of the IG counts were assessed in two ways. A flow cytometric IG count using CD11b, CD16, and CD45 monoclonal antibodies and a manual differential count were used as reference methods. The regression equation and the correlation coefficient of the IG% for the flow cytometric reference count versus results with the XE-IG Master were: y = 0.91x + 0.10; r = 0.96. For the comparison with the manual differential count of promyelocytes, myelocytes, and metamyelocytes, the regression equation and correlation coefficient were: y = 0.81x + 1.27; r = 0.78. Samples were found to be stable up to 48 hours both at room temperature and when refrigerated. We investigated the clinical significance of the IG count as a new marker of acute inflammation. In this preliminary study, most samples with a high IG count had positive values for C-reactive protein and the erythrocyte sedimentation rate (positive sample rates were 84.0% and 95.0%, respectively) despite neutrophil counts within the normal range. Elevated IG counts correlated most closely with CD64 expression on polymorphonuclear cells and less so with the concentration of interleukin 6. Compared with other available inflammation markers, the IG count is rapidly generated with each full blood count at no extra cost and with no delay in sample analysis.

摘要

我们使用XE-IG Master(Sysmex公司)评估了外周血中自动未成熟粒细胞(IG)计数。XE-IG Master是XE-2100自动血液分析仪的升级软件包。重复性测试显示,IG百分比(IG%)的平均变异系数为7.02%,绝对IG计数的平均变异系数为6.93%。IG计数的相关性通过两种方式进行评估。使用CD11b、CD16和CD45单克隆抗体的流式细胞术IG计数和手工分类计数用作参考方法。流式细胞术参考计数与XE-IG Master结果的IG%的回归方程和相关系数为:y = 0.91x + 0.10;r = 0.96。与早幼粒细胞、中幼粒细胞和晚幼粒细胞的手工分类计数进行比较时,回归方程和相关系数为:y = 0.81x + 1.27;r = 0.78。发现样本在室温下和冷藏时长达48小时都是稳定的。我们研究了IG计数作为急性炎症新标志物的临床意义。在这项初步研究中,大多数IG计数高的样本C反应蛋白和红细胞沉降率呈阳性(阳性样本率分别为84.0%和95.0%),尽管中性粒细胞计数在正常范围内。IG计数升高与多形核细胞上CD64的表达相关性最密切,与白细胞介素6的浓度相关性较小。与其他可用的炎症标志物相比,每次全血细胞计数时都能快速生成IG计数,无需额外费用,且样本分析无延迟。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验