Suppr超能文献

A multi-centre collaborative study on the potency estimation of ReFacto.

作者信息

Hubbard Anthony R, Sands Dawn, Sandberg Eva, Seitz Rainer, Barrowcliffe Trevor W

机构信息

Division of Haematology, National Institute for Biological Standards and Control, Blanche Lane, South Mimms, Potters Bar, Hertfordshire, EN6 3QG, United Kingdom.

出版信息

Thromb Haemost. 2003 Dec;90(6):1088-93. doi: 10.1160/TH03-02-0082.

Abstract

Seven laboratories estimated factor VIII coagulant activity in recombinant B-domain-deleted (ReFacto) and plasma-derived FVIII concentrates (Octonativ-M) using chromogenic methods relative to the WHO 6th International Standard FVIII Concentrate (WHO 6th IS), European Pharmacopoeia BRP#2 (EP#2) and the ReFacto Laboratory Standard (RLS). Significantly higher estimates were obtained for all batches of product when calculated relative to the RLS in comparison with estimates vs WHO 6th IS and EP#2. Mean estimates for two batches of ReFacto product vs the RLS were within 10% of the labelled potency whereas estimates vs WHO 6th IS and EP#2 ranged from 21 to 31% lower than the label. Conversely, mean estimates for Octonativ-M relative to WHO 6th IS and EP#2 were within 10% of the label whereas the mean estimate vs RLS was 117% of label. Mean estimates for the ReFacto product, vs the WHO 6th IS and EP#2, varied considerably between the different chromogenic kits whereas estimates vs the RLS showed good agreement between kits. Mean estimates for the RLS vs the WHO 6th IS (8.10 IU/vial) and the EP#2 (7.66 IU/vial) were lower than the assigned value of 9.4 IU/vial. The results are consistent with ReFacto and full-length FVIII responding differently to variations in assay methodology and also indicate that the assigned value on the RLS may be too high. Since this study the unitage on the RLS has been adjusted to effectively increase the amount of ReFacto in the product by 20%.

摘要

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验