Nxumalo J L, Teranaka M, Schenk W G
Arch Surg. 1978 Feb;113(2):169-72. doi: 10.1001/archsurg.1978.01370140059012.
Although many experimental studies have been made to determine the total hepatic blood flow in steady circulatory states, very few have been done in unsteady states of either circulatory overload or underload. In this experiment, a comparison is made between total hepatic blood flow measured by the single injection of indocyanine green and the electromagnetic flow methods in the dog, in which circulatory overload was induced by dextran 40 infusion. While there was close correlation between the values obtained by the two methods in normal dogs, following dextran infusion the indirect indocyanine green method overestimated hepatic blood flow by 40% to 60%, using the electromagnetic method as a comparison standard. The reason for this discrepancy is not elucidated by these studies.
尽管已经进行了许多实验研究来确定稳定循环状态下的肝脏总血流量,但在循环过载或循环不足的不稳定状态下进行的研究却很少。在本实验中,对通过单次注射吲哚菁绿测量的肝脏总血流量与电磁血流测量法在犬身上进行了比较,其中通过输注右旋糖酐40诱导循环过载。虽然在正常犬中两种方法获得的值之间存在密切相关性,但在输注右旋糖酐后,以电磁法作为比较标准,间接吲哚菁绿法高估肝脏血流量40%至60%。这些研究并未阐明这种差异的原因。