Suppr超能文献

在手臂测力计测试和游泳过程中测定的游泳运动员的生物能量特征。

Bioenergetic characteristics of swimmers determined during an arm-ergometer test and during swimming.

作者信息

Obert P, Falgairette G, Bedu M, Coudert J

机构信息

Laboratoire de la performance motrice, UFR STAPS, Université Blaise Pascal, Clermont-Ferrand.

出版信息

Int J Sports Med. 1992 May;13(4):298-303. doi: 10.1055/s-2007-1021270.

Abstract

The maximal oxygen uptake (VO2max) of 13 swimmers was determined by an arm-ergometer test (direct method) and estimated from a maximal multistage swimming test (indirect method) (23). A test-retest of the progressive swimming exercise showed that there were no significant differences from one test to the other and that there were significant correlations between the principal parameters: arm stroke index: 0.73, maximal aerobic swimming velocity: 0.94, VO2max: 0.95, p less than 0.01. Therefore, for swimmers of average ability, the reproducibility of this test has been proved. A significant difference (p less than 0.001) was observed between the two tests for VO2max: arm-ergometer test (VO2max arms): 2.4 +/- 0.5 l.min-1, swimming test (VO2max ST): 3.2 +/- 0.7 l.min-1, p less than 0.01. This difference appeared to be linked to the use of a greater muscle mass (arms and legs) during swimming. A significant correlation (r = 0.73, p less than 0.01) was obtained between VO2max (l.min-1) by using both the direct and indirect exercises as methods of measurement. However, the level of r did not permit the prediction of one parameter from the other. Significant correlations were obtained between VO2max and performances over 200 and 400 m free style regardless of the methodology used (VO2max arm, VO2max ST). Moreover, only VO2max (arm, ST) emerged as a variable accounting for swimming performance from a step-wise multiple regression analysis, in which biometric and bioenergetic parameters were taken into account.

摘要

通过手臂测力计测试(直接法)测定了13名游泳运动员的最大摄氧量(VO2max),并通过最大多级游泳测试(间接法)进行了估算(23)。对渐进式游泳运动的重测表明,两次测试之间没有显著差异,并且主要参数之间存在显著相关性:手臂划水指数:0.73,最大有氧游泳速度:0.94,VO2max:0.95,p小于0.01。因此,对于中等水平的游泳运动员,该测试的可重复性已得到证明。VO2max的两次测试之间观察到显著差异(p小于0.001):手臂测力计测试(VO2max手臂):2.4±0.5升·分钟-1,游泳测试(VO2max ST):3.2±0.7升·分钟-1,p小于0.01。这种差异似乎与游泳时使用更大的肌肉量(手臂和腿部)有关。使用直接和间接运动作为测量方法时,VO2max(升·分钟-1)之间获得了显著相关性(r = 0.73,p小于0.01)。然而,r值水平不允许从一个参数预测另一个参数。无论使用何种方法(VO2max手臂,VO2max ST),VO2max与200米和400米自由泳成绩之间均获得了显著相关性。此外,在考虑生物特征和生物能量参数的逐步多元回归分析中,只有VO2max(手臂,ST)作为一个变量能够解释游泳成绩。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验