Suppr超能文献

深蹲和纵跳测试的信度与因子效度

Reliability and factorial validity of squat and countermovement jump tests.

作者信息

Markovic Goran, Dizdar Drazan, Jukic Igor, Cardinale Marco

机构信息

Faculty of Kinesiology, University of Zagreb, Croatia.

出版信息

J Strength Cond Res. 2004 Aug;18(3):551-5. doi: 10.1519/1533-4287(2004)18<551:RAFVOS>2.0.CO;2.

Abstract

The primary aim of this study was to determine reliability and factorial validity of squat (SJ) and countermovement jump (CMJ) tests. The secondary aim was to compare 3 popular methods for the estimation of vertical jumping height. Physical education students (n = 93) performed 7 explosive power tests: 5 different vertical jumps (Sargent jump, Abalakow's jump with arm swing and without arm swing, SJ, and CMJ) and 2 horizontal jumps (standing long jump and standing triple jump). The greatest reliability among all jumping tests (Cronbach's alpha = 0.97 and 0.98) had SJ and CMJ. The reliability alpha coefficients for other jumps were also high and varied between 0.93 and 0.96. Within-subject variation (CV) in jumping tests ranged between 2.4 and 4.6%, the values being lowest in both horizontal jumps and CMJ. Factor analysis resulted in the extraction of only 1 significant principal component, which explained 66.43% of the variance of all 7 jumping tests. Since all jumping tests had high correlation coefficients with the principal component (r = 0.76-0.87), it was interpreted as the explosive power factor. The CMJ test showed the highest relationship with the explosive power factor (r = 0.87), that is, the greatest factorial validity. Other jumping tests had lower but relatively homogeneous correlation with the explosive power factor extracted. Based on the results of this study, it can be concluded that CMJ and SJ, measured by means of contact mat and digital timer, are the most reliable and valid field tests for the estimation of explosive power of the lower limbs in physically active men.

摘要

本研究的主要目的是确定深蹲(SJ)和反向纵跳(CMJ)测试的可靠性和因子效度。次要目的是比较3种常用的垂直跳跃高度估计方法。体育专业学生(n = 93)进行了7项爆发力测试:5种不同的垂直跳跃(萨金特纵跳、有摆臂和无摆臂的阿巴拉科夫纵跳、SJ和CMJ)以及2种水平跳跃(立定跳远和立定三级跳远)。所有跳跃测试中可靠性最高的(克朗巴哈系数α = 0.97和0.98)是SJ和CMJ。其他跳跃测试的可靠性α系数也很高,在0.93至0.96之间变化。跳跃测试中的受试者内变异(CV)在2.4%至4.6%之间,水平跳跃和CMJ中的该值最低。因子分析仅提取出1个显著的主成分,它解释了所有7项跳跃测试方差的66.43%。由于所有跳跃测试与主成分的相关系数都很高(r = 0.76 - 0.87),因此将其解释为爆发力因子。CMJ测试与爆发力因子的关系最为密切(r = 0.87),即具有最大的因子效度。其他跳跃测试与提取出的爆发力因子的相关性较低但相对均匀。基于本研究结果,可以得出结论,通过接触垫和数字计时器测量的CMJ和SJ是评估身体活跃男性下肢爆发力最可靠和有效的现场测试。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验