Suppr超能文献

使用Symmetry近端吻合装置进行冠状动脉搭桥手术的术中及中期血管造影结果。

Intraoperative and intermediate-term angiographic results of coronary artery bypass surgery with Symmetry proximal anastomotic device.

作者信息

Bergsland Jacob, Hol Per Kristian, Lingås Per Snorre, Lundblad Runar, Rein Kjell Arne, Andersen Rune, Mørk Bjørn Erik, Halvorsen Steinar, Mujanovic Emir, Kabil Emir, Svennevig Jan L, Fosse Erik

机构信息

Interventional Center, Rikshospitalet, Oslo, Norway.

出版信息

J Thorac Cardiovasc Surg. 2004 Nov;128(5):718-23. doi: 10.1016/j.jtcvs.2004.07.001.

Abstract

OBJECTIVE

The objective of this study was to investigate the patency in saphenous vein coronary bypass grafts in which the proximal anastomoses were performed with automatic connector devices or with a traditional suture technique.

METHODS

Forty-six patients underwent coronary artery bypass grafting without cardiopulmonary bypass by using one thoracic graft and one or more saphenous vein grafts. Grafts were attached to the aorta with a Symmetry connector (St Jude Medical, Inc, St Paul, Minn) in 23 patients, and partial occlusion of the aorta and sutured anastomoses were used in 23 other patients. Grafts were studied intraoperatively with transit time flowmetry and angiography and revised if necessary. Angiography was repeated after 3 to 5 months.

RESULTS

Intraoperative graft patency did not differ between the 2 groups. Follow-up angiography demonstrated excellent thoracic graft patency. Vein graft patency decreased to 50% in the Symmetry group, whereas it was 90% in the suture group ( P = .01). Twenty-five percent of the Symmetry grafts had significant stenosis in the connector.

CONCLUSION

Saphenous vein grafts anastomosed to aorta with the Symmetry proximal connector have low intermediate patency compared with those with traditionally sutured anastomoses. We do not recommend the routine use of this device in coronary artery bypass operations.

摘要

目的

本研究旨在调查大隐静脉冠状动脉搭桥术中使用自动连接装置或传统缝合技术进行近端吻合的血管通畅情况。

方法

46例患者在非体外循环下行冠状动脉搭桥术,使用一根胸廓内动脉移植物和一根或多根大隐静脉移植物。23例患者使用Symmetry连接器(圣犹达医疗公司,明尼苏达州圣保罗)将移植物与主动脉相连,另外23例患者采用部分阻断主动脉并进行缝合吻合的方法。术中采用通过时间血流测定法和血管造影术对移植物进行研究,必要时进行修正。3至5个月后重复血管造影。

结果

两组术中移植物通畅情况无差异。随访血管造影显示胸廓内动脉移植物通畅情况良好。Symmetry组静脉移植物通畅率降至50%,而缝合组为90%(P = 0.01)。25%的Symmetry移植物在连接器处有明显狭窄。

结论

与传统缝合吻合的大隐静脉移植物相比,使用Symmetry近端连接器与主动脉吻合的大隐静脉移植物中期通畅率较低。我们不建议在冠状动脉搭桥手术中常规使用该装置。