Nauschuetz W F, Harrison L S, Trevino S B, Becker G R, Benton J
Department of Pathology and Area Laboratory Services, Brooke Army Medical Center, Fort Sam Houston, Texas 78234-6200.
Curr Microbiol. 1993 Jan;26(1):43-5. doi: 10.1007/BF01577241.
Five hundred twenty-five random clean catch urine specimens, collected from 339 adult females, 137 adult males, and 49 pediatric patients, were screened for the presence of bacteriuria with the Uriscreen catalase test and with the Chemstrip 2 LN dipstick. Quantitative cultures were performed on all specimens. The sensitivity, specificity, positive predictive value, and negative predictive value for the catalase test, with 10(5) CFU/ml as the threshold for significant bacteriuria, were 91.3%, 72.3%, 33.7%, and 98.0%, respectively. Values for the dipstick were 83.9%, 77.9%, 43.7%, and 96.0%. When 10(4) CFU/ml was used as the threshold, the catalase test had a sensitivity of 89.2%, specificity of 70.4%, positive predictive value of 37.3%, and a negative predictive value of 97.0%. Values for the dipstick at that level were 82.3%, 77.5%, 48.6%, and 94.8%. While the catalase test was more sensitive than the dipstick, it was our opinion that high rates of false-negatives associated with these methods negated the convenience of these fast and simple urine screens.
从339名成年女性、137名成年男性和49名儿科患者中收集了525份随机清洁中段尿标本,使用Uriscreen过氧化氢酶试验和Chemstrip 2 LN试纸条筛查是否存在菌尿。对所有标本进行了定量培养。以10⁵CFU/ml作为显著菌尿的阈值时,过氧化氢酶试验的敏感性、特异性、阳性预测值和阴性预测值分别为91.3%、72.3%、33.7%和98.0%。试纸条的相应值分别为83.9%、77.9%、43.7%和96.0%。当以10⁴CFU/ml作为阈值时,过氧化氢酶试验的敏感性为89.2%,特异性为70.4%,阳性预测值为37.3%,阴性预测值为97.0%。该水平下试纸条的相应值分别为82.3%、77.5%、48.6%和94.8%。虽然过氧化氢酶试验比试纸条更敏感,但我们认为,与这些方法相关的高假阴性率抵消了这些快速简单的尿液筛查方法的便利性。