Abstract

Ir-192 seeds are widely used in the USA for low dose rate interstitial brachytherapy. There are two commercially available models: those manufactured by Best Industries filtered with stainless steel, and those manufactured by Alpha-Omega seeds filtered with Pt. Newly developed 3D correction algorithms for brachytherapy are based on dosimetry data obtained on unbounded phantom size, allowing corrections for heterogeneities and actual tissue boundaries. Published dosimetric datasets for both seeds have been obtained under bounded conditions. The aim of the present study is to obtain dosimetric datasets for these seeds under full scatter conditions. The Monte Carlo GEANT4 code has been used to estimate air-kerma strength and dose rate in water around the Ir-192 seeds. Functions and parameters following the TG43 formalism are obtained and presented in tabular forms: the dose rate constant, the radial dose function, and the anisotropy function. Tables for the anisotropy factor have been obtained in order to apply punctual approximation. Differences between dose rate distributions for both seeds show that specific dataset must be used for each type of seed in clinical dosimetry. The data in the present study improve on published data in the following aspects: (i) dosimetric data were obtained under full scatter conditions, which affect dose values at distances greater than 4-5 cm from the source; (ii) the dose rate tables are given at greater distances from the source; and (iii) the spatial resolution in high dose gradient areas, such as those near the longitudinal source axis, has been improved.

摘要

铱-192 籽源在美国被广泛用于低剂量率组织间近距离治疗。有两种市售型号:一种是由 Best Industries 制造、用不锈钢过滤的;另一种是由 Alpha-Omega 籽源制造、用铂过滤的。新开发的用于近距离治疗的三维校正算法基于在无界体模尺寸下获得的剂量学数据,可对不均匀性和实际组织边界进行校正。已公布的这两种籽源的剂量学数据集都是在有界条件下获得的。本研究的目的是在全散射条件下获得这些籽源的剂量学数据集。蒙特卡罗 GEANT4 代码已被用于估算铱-192 籽源周围水中的空气比释动能强度和剂量率。获得了遵循 TG43 形式主义的函数和参数,并以表格形式呈现:剂量率常数、径向剂量函数和各向异性函数。为了应用点近似,已获得各向异性因子表。两种籽源的剂量率分布差异表明,在临床剂量学中,每种类型的籽源必须使用特定的数据集。本研究中的数据在以下方面对已发表的数据有所改进:(i) 剂量学数据是在全散射条件下获得的,这会影响距源大于 4 - 5 厘米处的剂量值;(ii) 剂量率表给出的是距源更大距离处的数据;(iii) 在高剂量梯度区域,如纵向源轴附近区域的空间分辨率得到了提高。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验