Suppr超能文献

[NeuFlex硅橡胶植入物在掌指关节置换术中的早期结果]

[Early results of NeuFlex silastic implant in MCP arthroplasty].

作者信息

Schindele S, Herren D, Flury M, Simmen B R

机构信息

Abteilung für Obere Extremität und Handchirurgie, Schulthess-Klinik, Zürich, Schweiz.

出版信息

Handchir Mikrochir Plast Chir. 2005 Feb;37(1):13-7. doi: 10.1055/s-2004-830433.

Abstract

For the reconstruction of destroyed metacarpophalangeal (MP) joints in rheumatoid arthritis, the Swanson silicon spacer is still the golden standard. However, long-term follow-up reveals an increasing number of complications, particularly mechanical failure. In order to deal with these problems a number of new, biomechanically different silicone implants have been designed. Among these, the NeuFlex prosthesis has a preflexed hinge of 30 degrees in relation to the shaft axis, a more palmar lying center of rotation and a rectangular hinge with a collarlike platform against the bony surfaces. In a prospective study, the early results of the first thirteen patients operated with the NeuFlex arthroplasty are reported. All patients suffered from rheumatoid arthritis with destruction of the MP joints. The mean follow-up was 12.3 months. A total of 37 joints were replaced. All patients were female with an average age of 56 years. Postoperative reduction of pain, measured on a visual analog scale with the maximum of 10 (VAS), decreased from 6.6 to 0.7 (p < 0.001). Jamar grip strength improved from 4.2 kg preoperatively to 9.9 kg postoperatively (p < 0.005). Range of motion improved from 37 degrees to 57 degrees (p < 0.0001) as a result of a reduction in active extension deficit which reduced from 35 degrees to 15 degrees postoperatively. Ulnar drift was reduced from 20.2 degrees to 3.4 degrees at follow-up (p < 0.005). Radiological evaluation showed no implant failure, no subsidence, and no signs of inflammatory reaction. Overall the NeuFlex silicone implants show encouraging early results which must be confirmed in the long term.

摘要

对于类风湿性关节炎中毁损的掌指(MP)关节的重建,斯旺森硅树脂间隔物仍是金标准。然而,长期随访显示并发症数量不断增加,尤其是机械故障。为了解决这些问题,人们设计了一些新的、生物力学特性不同的硅树脂植入物。其中,NeuFlex假体相对于轴轴线有一个30度的预弯曲铰链,旋转中心更靠近手掌,还有一个带有类似领口平台的矩形铰链抵靠骨表面。在一项前瞻性研究中,报告了首批13例接受NeuFlex关节成形术患者的早期结果。所有患者均患有类风湿性关节炎且MP关节遭到破坏。平均随访时间为12.3个月。共置换了37个关节。所有患者均为女性,平均年龄56岁。术后疼痛减轻,采用视觉模拟评分法(满分10分,VAS)测量,从6.6降至0.7(p<0.001)。Jamar握力从术前的4.2千克提高到术后的9.9千克(p<0.005)。由于主动伸展缺损减少,活动范围从37度提高到57度(p<0.0001),术后主动伸展缺损从35度降至15度。随访时尺侧偏斜从20.2度降至3.4度(p<0.005)。放射学评估显示无植入物失败、无下沉且无炎症反应迹象。总体而言,NeuFlex硅树脂植入物显示出令人鼓舞的早期结果,但必须进行长期验证。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验