即时检测血红蛋白测量在使用HemoCue-B血红蛋白仪进行贫血初步诊断中的效用。

Utility of point-of-care haemoglobin measurement in the HemoCue-B haemoglobin for the initial diagnosis of anaemia.

作者信息

Muñoz M, Romero A, Gómez J F, Manteca A, Naveira E, Ramírez G

机构信息

Department of Biochemistry and Molecular Biology, School of Medicine, University of Málaga, Málaga, Spain.

出版信息

Clin Lab Haematol. 2005 Apr;27(2):99-104. doi: 10.1111/j.1365-2257.2005.00678.x.

Abstract

Measurement of haemoglobin (Hb) concentration provides a reliable indication of the presence and severity of anaemia. However, other laboratory parameters are usually requested as well, leading to an increase in socio-sanitary costs. Accordingly, this study was undertaken to ascertain the reliability of point-of-care Hb determination with the portable photometer HemoCue-B haemoglobin (HBH) and to evaluate its utility for the initial diagnosis of anaemia. Hb was measured (x3) in 20 venous blood samples diluted with saline (v/v; 1 : 0, 2 : 1, 1 : 1, 2 : 1 and 3 : 1) to obtain a wide range of Hb and in venous and capillary blood samples from 247 primary health care patients. All HBH results were compared with those yielded by the reference cell counter Pentra 120 Retic (ABX). In diluted samples, Hb values obtained with either method were not significantly different (ABX-HBH, -0.01 +/- 0.32 g/dl; 95% CI, -0.04 to 0.028 g/dl) and showed an excellent Pearson's coefficient of correlation (r = 0.992; P < 0.01). HBH provides accurate values if at least 4 mul of blood is loaded into the cuvette. There were no significant differences between Hb measured in venous (v) and capillary (c) blood samples in primary care patients. Eighteen anaemic patients were detected by ABX measurements (7.3%; 15 female/3 male), 18 by HBHv (specificity, 100%; sensitivity, 100%) and 25 by HBHc (eight false positives; one false negative; specificity, 94.4%; sensitivity, 96.5%). Compared with ABX, HBH provides accurate and precise measurements for a wide range of Hb and its use in primary health care seems to be a good method for the initial diagnosis of anaemia.

摘要

血红蛋白(Hb)浓度的测定能可靠地指示贫血的存在及严重程度。然而,通常还需要检测其他实验室参数,这导致社会卫生成本增加。因此,本研究旨在确定便携式光度计HemoCue - B血红蛋白仪(HBH)进行即时检测Hb的可靠性,并评估其在贫血初步诊断中的效用。对20份用生理盐水稀释(体积比;1 : 0、2 : 1、1 : 1、2 : 1和3 : 1)的静脉血样本进行Hb测量(3次),以获得广泛的Hb范围,并对247名初级卫生保健患者的静脉血和毛细血管血样本进行检测。将所有HBH检测结果与参考血细胞计数器Pentra 120 Retic(ABX)的结果进行比较。在稀释样本中,两种方法获得的Hb值无显著差异(ABX - HBH,-0.01±0.32 g/dl;95%可信区间,-0.04至0.028 g/dl),且显示出极佳的皮尔逊相关系数(r = 0.992;P < 0.01)。如果至少4微升血液装入比色皿,HBH可提供准确值。初级保健患者静脉血(v)和毛细血管血(c)样本中测量的Hb无显著差异。ABX检测出18例贫血患者(7.3%;15名女性/3名男性),HBHv检测出18例(特异性,100%;敏感性,100%),HBHc检测出25例(8例假阳性;1例假阴性;特异性,94.4%;敏感性,96.5%)。与ABX相比,HBH能对广泛的Hb范围进行准确且精确的测量,其在初级卫生保健中的应用似乎是贫血初步诊断的一种良好方法。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验