Suppr超能文献

眼压的短期升高并不会改变视网膜和视神经乳头血流对闪烁刺激的反应。

Short-term increase of intraocular pressure does not alter the response of retinal and optic nerve head blood flow to flicker stimulation.

作者信息

Garhöfer Gerhard, Resch Hemma, Weigert Günther, Lung Solveig, Simader Christian, Schmetterer Leopold

机构信息

Departments of Clinical Pharmacology, Medical University of Vienna, Währinger Gürtel 18-20, A-1090 Vienna, Austria.

出版信息

Invest Ophthalmol Vis Sci. 2005 May;46(5):1721-5. doi: 10.1167/iovs.04-1347.

Abstract

PURPOSE

It has been shown that stimulation with diffuse luminance flicker induces vasodilatation in the human retina and increases optic nerve head (ONH) blood flow. The present study was designed to investigate the influence of a short-term increase in intraocular pressure on flicker-induced changes in ONH blood flow and retinal vessel diameters.

METHODS

In a group of 15 healthy volunteers, IOP was increased by the episcleral suction cup technique. ONH blood flow was assessed with a laser Doppler flowmeter, and retinal vessel diameters were measured with the retinal vessel analyzer. Flicker responses of retinal vessel diameters and ONH blood flow were determined at baseline conditions and during suction of 70 and 140 mm Hg. Flicker light consisted of 8-Hz square-wave flashes at a wavelength below 550 nm and produced a retinal irradiance of 140 muW/cm(2).

RESULTS

Suction increased IOP from 12 +/- 2 to 27 +/- 4 mm Hg and 43 +/- 4 mm Hg. Stimulation with diffuse luminance flicker induced an increase in ONH blood flow of +24.0% +/- 20.7%. Increased IOP did not significantly change the flicker response in the ONH (+19.3% +/- 26.6% and +22.1% +/- 25.1%). In retinal veins, flicker induced an increase in vessel diameter of +3.0% +/- 2.0%. Flicker responses in retinal veins were not significantly altered after the IOP was increased, compared with those recorded at baseline IOP (+2.8% +/- 2.5% and +3.2% +/- 2.2%). The flicker response in retinal arteries at baseline IOP was +3.5% +/- 2.0%. Again, the increase in IOP did not significantly alter this flicker response (+2.8% +/- 1.6% and +3.1% +/- 2.4%).

CONCLUSIONS

A short-term increase in IOP does not alter the response of retinal vessel diameters and ONH blood flow to diffuse luminance flicker, which indicates that increased IOP does not alter retinal or ONH regulation during neuronal stimulation.

摘要

目的

研究表明,漫射亮度闪烁刺激可使人视网膜血管扩张,并增加视神经乳头(ONH)的血流量。本研究旨在探讨短期内眼压升高对闪烁诱导的ONH血流量变化及视网膜血管直径的影响。

方法

对15名健康志愿者采用巩膜吸盘技术升高眼压。用激光多普勒血流仪评估ONH血流量,用视网膜血管分析仪测量视网膜血管直径。在基线条件下以及眼压分别升至70和140 mmHg时,测定视网膜血管直径和ONH血流量的闪烁反应。闪烁光由波长低于550 nm的8 Hz方波闪光组成,视网膜辐照度为140 μW/cm²。

结果

吸盘抽吸使眼压从12±2 mmHg分别升至27±4 mmHg和43±4 mmHg。漫射亮度闪烁刺激使ONH血流量增加了24.0%±20.7%。眼压升高并未显著改变ONH的闪烁反应(分别为19.3%±26.6%和22.1%±25.1%)。在视网膜静脉中,闪烁使血管直径增加了3.0%±2.0%。与基线眼压时记录的结果相比,眼压升高后视网膜静脉的闪烁反应无显著改变(分别为2.8%±2.5%和3.2%±2.2%)。基线眼压时视网膜动脉的闪烁反应为3.5%±2.0%。同样,眼压升高并未显著改变该闪烁反应(分别为2.8%±1.6%和3.1%±2.4%)。

结论

短期内眼压升高不会改变视网膜血管直径和ONH血流量对漫射亮度闪烁的反应,这表明眼压升高不会改变神经元刺激期间视网膜或ONH的调节。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验