Comparison of transepidermal water loss and spectroscopic absorbance to quantify changes of the stratum corneum after tape stripping.

作者信息

Weigmann H-J, Ulrich J, Schanzer S, Jacobi U, Schaefer H, Sterry W, Lademann J

机构信息

Department of Dermatology, Center of Experimental and Applied Cutaneous Physiology, Charité - Universitatsmedizin Berlin, Berlin, Germany.

出版信息

Skin Pharmacol Physiol. 2005 Jul-Aug;18(4):180-5. doi: 10.1159/000085863. Epub 2005 May 20.

Abstract

The objective and quantitative application of tape stripping in pharmaceutics and dermatopharmacokinetics requires the determination of the exact position of each removed tape strip inside the stratum corneum (SC) and/or the determination of the relative SC thickness. In this study, transepidermal water loss (TEWL) and the optical spectroscopic data of the corneocytes were measured simultaneously during the complete removal of the SC by tape stripping. The spectroscopic data quantitatively reflect the amount of corneocytes removed by the individual tape strips, whereas TEWL and 1/TEWL are not sensitive enough to measure the relatively small changes in the SC thickness realized by the removal of the individual strips. The relative SC thickness can be determined directly by the spectroscopic data, while the 1/TEWL values require a second independent method. The results demonstrate the importance of tape stripping characterizing the behaviour of topically applied substances.

摘要

在药剂学和皮肤药代动力学中,胶带剥离的客观定量应用需要确定角质层(SC)内每条移除胶带的精确位置和/或相对SC厚度。在本研究中,在通过胶带剥离完全去除SC的过程中,同时测量了经表皮水分流失(TEWL)和角质形成细胞的光谱数据。光谱数据定量反映了各条胶带去除的角质形成细胞数量,而TEWL和1/TEWL对于测量因去除单条胶带而导致的SC厚度相对较小的变化不够敏感。相对SC厚度可直接由光谱数据确定,而1/TEWL值需要第二种独立方法。结果证明了胶带剥离在表征局部应用物质行为方面的重要性。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验