This study reports on a spectrophotometric assay for the determination of serum fructosamine concentration. The assay was evaluated for use in canine serum samples by assessment of the precision, accuracy, detectability and stability of serum fructosamine during storage. To evaluate the diagnostic usefulness of the assay, both the effect of acute changes in blood glucose on serum fructosamine concentration and the serum fructosamine concentration in canine diabetes mellitus and other canine diseases were studied. The main conclusions can be summarized as follows: Determination of canine serum fructosamines may be achieved by a precise and accurate assay with a detection limit well below the serum fructosamine concentration normally found in canine sera. Storage for 5 days at +4 degrees C or +25 degrees C, or for 28 days at -20 degrees C caused no significant change in serum fructosamine concentration. The concentration is not affected by acute changes in blood glucose. In diabetic dogs, serum fructosamine concentration is significantly greater than in dogs with other diseases.
本研究报告了一种用于测定血清果糖胺浓度的分光光度法。通过评估血清果糖胺在储存期间的精密度、准确性、可检测性和稳定性,对该检测方法在犬血清样本中的应用进行了评估。为了评估该检测方法的诊断实用性,研究了血糖急性变化对血清果糖胺浓度的影响以及犬糖尿病和其他犬类疾病中的血清果糖胺浓度。主要结论可总结如下:通过一种精确且准确的检测方法可以测定犬血清果糖胺,其检测限远低于犬血清中通常发现的血清果糖胺浓度。在4℃或25℃下储存5天,或在-20℃下储存28天,血清果糖胺浓度均无显著变化。该浓度不受血糖急性变化的影响。在糖尿病犬中,血清果糖胺浓度显著高于患有其他疾病的犬。