Although automated continuous-monitoring blood culture systems are both rapid and sensitive, false-positive and false-negative results still occur. The objective of this study, then, was to evaluate negative results occurring with BacT/Alert 3D blood culture systems. A total of 1032 samples were cultured with the BacT/Alert 3D automated blood culture system, using both aerobic (FA) and anaerobic (FN) [corrected] media, and 128 of these samples yielded positive results. A total of 904 negative blood samples were then subcultured in 5% sheep blood agar, eosin methylene blue, chocolate agar, and sabouraud-dextrose agar. Organisms growing on these subcultures were subsequently identified using both Vitek32 (bioMerieux, Durham, NC) and conventional methods. Twenty four (2.6%) of the 904 subcultures grew on the subculture media. The majority (83.3%) of these were determined to be gram-positive microorganisms. Fourteen (58.3%) were coagulase-negative staphylococci, two (8.3%) were Bacillus spp., one (4.2%) was Staphylococcus aureus, and one (4.2%) was identified as Enterococcus faecium. Streptococcus pneumoniae and Neisseria spp. were isolated together in two (8.3%) vials. Gram-negative microorganisms comprised 12.5% of the subcultures, of which two (8.3%) were found to be Pseudomonas aeruginosa, and one (4.2%) was Pseudomonas fluorescens. The other isolate (4.2%) was identified as Candida albicans. We conclude that the subculture of negative results is valuable in the BacT/Alert 3D system, especially in situations in which only one set of blood cultures is taken.

摘要

尽管自动化连续监测血培养系统既快速又灵敏,但仍会出现假阳性和假阴性结果。因此,本研究的目的是评估BacT/Alert 3D血培养系统出现的阴性结果。使用需氧(FA)和厌氧(FN)[已校正]培养基,共1032份样本通过BacT/Alert 3D自动化血培养系统进行培养,其中128份样本培养结果为阳性。然后,将总共904份阴性血样本接种于5%绵羊血琼脂、伊红美蓝琼脂、巧克力琼脂和沙氏葡萄糖琼脂中进行传代培养。随后使用Vitek32(bioMerieux公司,北卡罗来纳州达勒姆)和传统方法对这些传代培养物中生长的微生物进行鉴定。904份传代培养物中有24份(2.6%)在传代培养基上生长。其中大多数(83.3%)被确定为革兰氏阳性微生物。14份(58.3%)为凝固酶阴性葡萄球菌,2份(8.3%)为芽孢杆菌属,1份(4.2%)为金黄色葡萄球菌,1份(4.2%)被鉴定为粪肠球菌。在2份(8.3%)小瓶中共同分离出肺炎链球菌和奈瑟菌属。革兰氏阴性微生物占传代培养物的12.5%,其中2份(8.3%)为铜绿假单胞菌,1份(4.2%)为荧光假单胞菌。另一种分离株(4.2%)被鉴定为白色念珠菌。我们得出结论,在BacT/Alert 3D系统中,对阴性结果进行传代培养很有价值,尤其是在仅采集一组血培养样本的情况下。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验