Qin Yurong, Liao Yiwen, Zhou Jingfang, Liu Weijiang, Chen Huimin, Chen Xiaoli, Wang Weisha, Zhang Ni, Zhao Yunhu, Wang Liang, Gu Bing, Liu Suling
Guangdong Cardiovascular Institute, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangzhou, Guangdong, China.
Department of Laboratory Medicine, Guangdong Provincial People's Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou, Guangdong, China.
Microbiol Spectr. 2025 Jan 7;13(1):e0185024. doi: 10.1128/spectrum.01850-24. Epub 2024 Nov 29.
Bloodstream infections (BSI) pose significant threats to patient health, necessitating timely and accurate diagnostics to reduce mortality and morbidity. This study aimed to evaluate the clinical performance of the BacT/ALERT VIRTUO blood culture system with FANPlus bottles compared to the BACTEC FX400 system in detecting bloodstream pathogens. A total of 1,772 blood specimens were collected from various hospital wards. Specimen selection criteria were based on clinical suspicion of bloodstream infections, ensuring the inclusion of relevant and representative patient samples. These blood samples, collected from the same suspected sepsis patients, were cultured in parallel using both the BacT/ALERT VIRTUO and BACTEC FX400 systems. The diagnostic efficiency of both systems, including detection rates, time to detection (TTD), and sensitivity across different bacterial species, was assessed. In various application scenarios, the VIRTUO system demonstrates a higher positive detection rate, whether in the intensive care unit (ICU) (8.5% vs 6.4%, = 0.028) or in general wards. Additionally, for different types of bacteria, the TVIRTUO system exhibits superior detection rates for anaerobic bacteria (5.9% vs 3.2%, < 0.001) and aerobic bacteria (9.1% vs 7.2%, = 0.043). Furthermore, it boasts a shorter median TTD of 14 hours compared to 16 hours, and a higher sensitivity for Gram-positive bacteria (2.8% vs 1.6%, < 0.001). These findings emphasize VIRTUO's effectiveness in enhancing diagnostic accuracy, achieving faster time to detection, and expanding the spectrum of detected organisms, thereby facilitating the quicker initiation of appropriate therapies, supporting precise clinical decision-making, and ultimately improving patient outcomes.IMPORTANCEOur study conducted a critical evaluation of advanced blood culture technologies for managing bloodstream infections (BSI). A distinctive strength of our research is the large sample size and the concurrent testing of the same patients with two systems, a methodology rarely achieved in other studies. BSIs present severe health threats, necessitating prompt and accurate diagnostics to mitigate morbidity and mortality. The BacT/ALERT VIRTUO system, in comparison to the BACTEC FX400 system, demonstrated superior detection capabilities, emphasizing the critical role of advanced diagnostics in clinical settings.
血流感染(BSI)对患者健康构成重大威胁,因此需要及时、准确的诊断以降低死亡率和发病率。本研究旨在评估配备FANPlus瓶的BacT/ALERT VIRTUO血培养系统与BACTEC FX400系统在检测血流病原体方面的临床性能。共从医院各个病房收集了1772份血标本。标本选择标准基于对血流感染的临床怀疑,以确保纳入相关且具有代表性的患者样本。这些从同一疑似脓毒症患者采集的血样,同时使用BacT/ALERT VIRTUO和BACTEC FX400系统进行培养。评估了两个系统的诊断效率,包括检出率、检测时间(TTD)以及不同细菌种类的敏感性。在各种应用场景中,VIRTUO系统均显示出更高的阳性检出率,无论是在重症监护病房(ICU)(8.5%对6.4%,P = 0.028)还是在普通病房。此外,对于不同类型的细菌,VIRTUO系统对厌氧菌(5.9%对3.2%,P < 0.001)和好氧菌(9.1%对7.2%,P = 0.043)的检出率更高。此外,与16小时相比,它的中位TTD更短,为14小时,对革兰氏阳性菌的敏感性更高(2.8%对1.6%,P < 0.001)。这些发现强调了VIRTUO在提高诊断准确性、实现更快检测时间以及扩大检测微生物谱方面的有效性,从而有助于更快地开始适当治疗,支持精确的临床决策,并最终改善患者预后。重要性我们的研究对用于管理血流感染(BSI)的先进血培养技术进行了严格评估。我们研究的一个显著优势是样本量大,并且对同一患者使用两个系统同时进行检测,这是其他研究很少能做到的方法。血流感染对健康构成严重威胁,需要迅速、准确的诊断以减轻发病率和死亡率。与BACTEC FX400系统相比,BacT/ALERT VIRTUO系统显示出卓越的检测能力,强调了先进诊断在临床环境中的关键作用。