Wroblewski B M, Siney P D, Fleming P A
The John Charnley Research Institute, Wrightington Hospital, Hall Lane, Appley Bridge, Wigan WN6 9EP, England, UK.
J Bone Joint Surg Br. 2005 Sep;87(9):1220-1. doi: 10.1302/0301-620X.87B9.16265.
We report the results of our continued review of 11 total hip arthroplasties using 22.225 mm alumina ceramic femoral heads on a Charnley flanged stem, articulating with chemically cross-linked polyethylene. There was an initial bedding-in of up to 0.41 mm at the articular surface in the first two years. This had not progressed further, at a minimum follow-up of 15 years. Radiographically no femoral or acetabular component showed loosening or osteolysis.
我们报告了对11例全髋关节置换术的持续评估结果,这些手术使用的是22.225毫米氧化铝陶瓷股骨头,安装在Charnley带凸缘柄上,与化学交联聚乙烯进行关节连接。在最初的两年中,关节表面的初始磨合达0.41毫米。在至少15年的随访中,这种情况没有进一步发展。影像学检查显示,股骨或髋臼部件均未出现松动或骨溶解。