To determine whether five changes to our hyperopic LASIK protocol produced better outcomes.
Five changes, both technical and surgical, were instituted for the treatment of hyperopia. These five changes were nomogram refinements accounting for accommodation, use of a 7.0-mm optical zone and a 9.5-mm transition zone, a targeted mean flap diameter of 10.5 mm, sequential interruption of the laser ablation, and cleaning of the interface. The study comprised 43 eyes undergoing LASIK for hyperopia or hyperopic astigmatism with a mean preoperative spherical equivalent refraction of +2.28 diopters (D), a mean sphere of +1.93 D (range: +4.25 to +0.25 D), and mean cylinder of +1.10 D (range: +4.50 to +0.25 D). The NIDEK CXII excimer laser was used for all treatments.
From 1 day to 3 months postoperatively, the mean hyperopic shift was <0.50 D. Postoperatively, the number of patients achieving a distance best spectacle-corrected visual acuity (BSCVA) of 20/20 gradually increased to 93% by 3 months. The number of eyes that achieved 20/15 increased by 11.7% compared to preoperatively. Eighty-eight percent of eyes maintained or gained lines of BSCVA. Four patients lost 1 line of BSCVA. One patient lost >1 line of vision due to visually significant microstriae.
The outcomes support the observation that five surgical and technical modifications to the hyperopic LASIK procedure result in excellent visual quality and refractive outcomes and a low rate of regression.
确定对我们的远视性准分子原位角膜磨镶术(LASIK)方案所做的五项改变是否能产生更好的效果。
对远视治疗实施了五项技术和手术方面的改变。这五项改变包括:考虑调节因素的验光配镜法改进、使用7.0毫米的光学区和9.5毫米的过渡区、目标平均瓣直径为10.5毫米、激光消融的顺序中断以及界面清洁。该研究包括43只接受LASIK治疗远视或远视散光的眼睛,术前平均等效球镜度为+2.28屈光度(D),平均球镜为+1.93 D(范围:+4.25至+0.25 D),平均柱镜为+1.10 D(范围:+4.50至+0.25 D)。所有治疗均使用NIDEK CXII准分子激光。
术后1天至3个月,平均远视漂移<0.50 D。术后,实现最佳矫正视力(BSCVA)为20/20的患者数量在3个月时逐渐增加至93%。与术前相比,达到20/15的眼睛数量增加了11.7%。88%的眼睛维持或提高了BSCVA的行数。4名患者的BSCVA下降了1行。1名患者因明显的视觉微条纹导致视力下降超过1行。
这些结果支持这样的观察,即对远视性LASIK手术进行的五项手术和技术改进可带来优异的视觉质量和屈光效果以及低回退率。