Abstract

AIMS

To compare the performance of the Sentinel blood culture system with two other systems for the recovery of streptococci and anaerobes.

METHODS

Blood cultures were taken from 55 patients one to two minutes after dental extraction. The samples were tested by the radiometric Bactec 460; the Isolator 10, which works by lysis centrifugation; and Sentinel, a fully automated system, which detects bacterial growth by changes in the voltage between two electrodes in the media. Positive samples were subcultured and streptococci and anaerobes were further identified. Terminal subcultures were performed on all negative samples.

RESULTS

Sentinel was comparable with Bactec, with Sentinel recovering 20 streptococci and 14 anaerobes; Bactec isolated 26 streptococci and 15 anaerobes. The recovery of Streptococcus sanguis was significantly better from Bactec than Sentinel. The Isolator 10 recovered significantly fewer streptococci and anaerobes than either Bactec or Sentinel. Sentinel was noticeably quicker in detecting anaerobes than Bactec 460. However, there was no comparable difference with streptococci. Contaminants were recovered from 10% of Isolator 10, 2.7% of Bactec, and 7.2% of Sentinel bottles.

CONCLUSIONS

Sentinel and Bactec 460 were broadly comparable in the detection of viridans streptococci and oral anaerobes, and both systems were significantly better than the Isolator 10. However, the prototype Sentinel, was significantly poorer than Bactec for the recovery of S sanguis.

摘要

目的

比较哨兵血培养系统与其他两种系统对链球菌和厌氧菌的分离效果。

方法

在55例患者拔牙后1至2分钟采集血培养样本。样本分别采用放射性测量的Bactec 460系统、通过裂解离心工作的Isolator 10系统以及通过检测培养基中两个电极之间电压变化来检测细菌生长的全自动哨兵系统进行检测。阳性样本进行传代培养,并进一步鉴定链球菌和厌氧菌。对所有阴性样本进行最终传代培养。

结果

哨兵系统与Bactec系统相当,哨兵系统分离出20株链球菌和14株厌氧菌;Bactec系统分离出26株链球菌和15株厌氧菌。从Bactec系统中分离出血链球菌的效果明显优于哨兵系统。Isolator 10系统分离出的链球菌和厌氧菌明显少于Bactec系统和哨兵系统。哨兵系统检测厌氧菌的速度明显快于Bactec 460系统。然而,在检测链球菌方面没有类似差异。从10%的Isolator 10系统样本、2.7%的Bactec系统样本和7.2%的哨兵系统样本中检测到污染物。

结论

在检测草绿色链球菌和口腔厌氧菌方面,哨兵系统和Bactec 460系统大致相当,且这两种系统均明显优于Isolator 10系统。然而,原型哨兵系统在分离血链球菌方面明显不如Bactec系统。