Abstract

The Isolator 1.5 microbial tube (E. I. du Pont de Nemours & Co., Inc., Wilmington , Del.) was compared with the BACTEC radiometric detection system (Johnston Laboratories, Inc., Cockeysville, Md.) for the detection of bacteremia in children. The Isolator 1.5 is a blood culture system designed for small volumes of blood (0.5 to 1.5 ml). The method involves lysis of the cells of the patient and the direct plating of the entire blood lysate on agar media appropriate for the growth of fastidious microorganisms. Of 1,500 paired samples inoculated into the two systems, 68 were positive for 73 clinically significant organisms. The Isolator 1.5 recovered 81% of the positive cultures compared with 84% recovered by the BACTEC system. When paired blood samples with disproportionate volumes were excluded, the Isolator 1.5 detected 3% more positive cultures. More isolates of Streptococcus pneumoniae and Neisseria meningitidis were recovered by the Isolator 1.5, whereas Haemophilus influenzae was recovered most often in the BACTEC bottles (P greater than 0.1). The contamination rates were 8.7 and 3.1% for the Isolator 1.5 and the BACTEC system, respectively. In cultures positive by both systems, the mean time to detection was 4.1 h faster with the Isolator 1.5. The mean time to obtain isolated colonies was 26.6 h faster with the Isolator 1.5. These data indicate the potential value of the Isolator 1.5 microbial tube as a simple, rapid, and sensitive method for the detection of bacteremia in children.

摘要

将用于儿童菌血症检测的Isolator 1.5微生物管(E. I. 杜邦公司,特拉华州威尔明顿)与BACTEC放射测量检测系统(约翰斯顿实验室公司,马里兰州科基斯维尔)进行了比较。Isolator 1.5是一种用于少量血液(0.5至1.5毫升)的血培养系统。该方法包括裂解患者细胞,并将全血裂解物直接接种在适合苛养微生物生长的琼脂培养基上。在接种到这两种系统的1500对样本中,有68对样本对73种具有临床意义的微生物呈阳性。Isolator 1.5系统检测出81%的阳性培养物,而BACTEC系统检测出84%。当排除体积不成比例的配对血样后,Isolator 1.5系统检测出的阳性培养物多3%。Isolator 1.5系统分离出的肺炎链球菌和脑膜炎奈瑟菌更多,而流感嗜血杆菌在BACTEC瓶中分离得最为常见(P大于0.1)。Isolator 1.5系统和BACTEC系统的污染率分别为8.7%和3.1%。在两种系统均呈阳性的培养物中,Isolator 1.5系统的平均检测时间快4.1小时。Isolator 1.5系统获得分离菌落的平均时间快26.6小时。这些数据表明Isolator 1.5微生物管作为一种用于儿童菌血症检测的简单、快速且灵敏的方法具有潜在价值。

相似文献

引用本文的文献

本文引用的文献

1
False no-growth blood cultures in pneumococcal pneumonia.肺炎球菌肺炎血培养假阴性结果
J Clin Microbiol. 1980 Oct;12(4):572-5. doi: 10.1128/jcm.12.4.572-575.1980.
8
Effect of sodium polyanethol sulfonate in blood cultures.聚茴香脑磺酸钠在血培养中的作用。
J Clin Microbiol. 1975 Feb;1(2):119-23. doi: 10.1128/jcm.1.2.119-123.1975.
10
New centrifugation blood culture device.新型离心式血液培养装置。
J Clin Microbiol. 1978 Jan;7(1):52-4. doi: 10.1128/jcm.7.1.52-54.1978.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验