Suppr超能文献

黄斑旁毛细血管白细胞速度的直接和非侵入性评估。

Direct and noninvasive assessment of parafoveal capillary leukocyte velocity.

作者信息

Martin Joy A, Roorda Austin

机构信息

College of Optometry, University of Houston, Houston, Texas, USA.

出版信息

Ophthalmology. 2005 Dec;112(12):2219-24. doi: 10.1016/j.ophtha.2005.06.033. Epub 2005 Oct 27.

Abstract

PURPOSE

Alterations in leukocyte velocity have been implicated in many retinal disease processes. However, direct and objective assessment of leukocyte velocity in retinal capillaries has been limited by a reliance on invasive contrast dyes that allow leukocyte visualization only for a short time span. The recent application of adaptive optics in a scanning laser ophthalmoscope (AOSLO) has made long-term imaging of parafoveal leukocyte movement possible without contrast dyes. In this study, using the AOSLO, we demonstrate a new method to investigate retinal parafoveal capillary leukocyte velocity.

DESIGN

Experimental study.

PARTICIPANTS

Six normal healthy subjects ranging from 25 to 35 years of age with clear ocular media.

METHODS

The parafoveal zone of the retina was imaged in all subjects using an AOSLO.

MAIN OUTCOME MEASURES

Leukocyte velocity was determined in the parafoveal capillaries including the foveal avascular zone border. Leukocyte velocity was measured directly from movie segments in which the leukocytes were clearly visible.

RESULTS

The mean parafoveal leukocyte velocity for 6 subjects was 1.37 mm/second, ranging from 0.77 to 2.10 mm/second. Leukocytes were not visible in all parafoveal capillaries.

CONCLUSIONS

Parafoveal capillary leukocyte velocity can be directly and noninvasively measured without the use of contrast dyes using an AOSLO.

摘要

目的

白细胞速度改变与许多视网膜疾病进程有关。然而,视网膜毛细血管中白细胞速度的直接和客观评估一直受到限制,因为依赖侵入性造影剂,而这些造影剂只能在短时间内使白细胞可视化。自适应光学技术最近在扫描激光检眼镜(AOSLO)中的应用使得在不使用造影剂的情况下对黄斑旁白细胞运动进行长期成像成为可能。在本研究中,我们使用AOSLO展示了一种研究视网膜黄斑旁毛细血管白细胞速度的新方法。

设计

实验研究。

参与者

6名年龄在25至35岁之间、眼内介质清晰的正常健康受试者。

方法

使用AOSLO对所有受试者的视网膜黄斑旁区域进行成像。

主要观察指标

测定包括黄斑无血管区边界在内的黄斑旁毛细血管中的白细胞速度。直接从白细胞清晰可见的电影片段中测量白细胞速度。

结果

6名受试者的平均黄斑旁白细胞速度为1.37毫米/秒,范围为0.77至2.10毫米/秒。并非所有黄斑旁毛细血管中都能看到白细胞。

结论

使用AOSLO无需使用造影剂即可直接且无创地测量黄斑旁毛细血管白细胞速度。