Suppr超能文献

热稀释法与菲克法在测量心输出量时缺乏一致性。

Lack of agreement between thermodilution and fick methods in the measurement of cardiac output.

作者信息

Baylor Peter

机构信息

Veterans Administration Central California Health Care System, Fresno, CA 93703, USA.

出版信息

J Intensive Care Med. 2006 Mar-Apr;21(2):93-8. doi: 10.1177/0885066605285234.

Abstract

A comparison between the thermodilution method and the Fick method of cardiac output measurement in 30 critically ill patients was performed. Although there was good correlation between both methods, there was poor agreement. The Bland and Altman method of assessing agreement between 2 measurements is the preferred method of agreement assessment. The variables possibly responsible for this disagreement are noted.

摘要

对30例危重症患者采用热稀释法和菲克法测量心输出量进行了比较。虽然两种方法之间存在良好的相关性,但一致性较差。评估两次测量之间一致性的布兰德和奥特曼方法是首选的一致性评估方法。文中指出了可能导致这种不一致的变量。