Suppr超能文献

Continuous non-invasive cardiac output monitoring during exercise: validation of electrical cardiometry with Fick and thermodilution methods.

作者信息

Liu Y H, Dhakal B P, Keesakul C, Kacmarek R M, Lewis G D, Jiang Y

机构信息

Beijing, China Boston, MA, USA.

Boston, MA, USA.

出版信息

Br J Anaesth. 2016 Jul;117(1):129-31. doi: 10.1093/bja/aew156.

Abstract
摘要

相似文献

3
Accuracy and precision of non-invasive cardiac output monitoring by electrical cardiometry: a systematic review and meta-analysis.
J Clin Monit Comput. 2020 Jun;34(3):433-460. doi: 10.1007/s10877-019-00330-y. Epub 2019 Jun 7.
5
[Estimating cardiac output. Utility in the clinical practice. Available invasive and non-invasive monitoring].
Med Intensiva. 2011 Dec;35(9):552-61. doi: 10.1016/j.medin.2011.01.014. Epub 2011 Mar 15.
6
Frequently repeated Fick cardiac output measurements during anesthesia.
J Clin Monit. 1990 Apr;6(2):107-12. doi: 10.1007/BF02828286.
7
Continuous thermodilution cardiac output monitoring during therapeutic hypothermia.
Anesth Analg. 2011 Jan;112(1):250-1. doi: 10.1213/ANE.0b013e3181f33910.
8
Continuous cardiac output: myth or reality?
Can J Anaesth. 1993 Feb;40(2):98-102. doi: 10.1007/BF03011304.

本文引用的文献

1
Mechanisms of exercise intolerance in heart failure with preserved ejection fraction: the role of abnormal peripheral oxygen extraction.
Circ Heart Fail. 2015 Mar;8(2):286-94. doi: 10.1161/CIRCHEARTFAILURE.114.001825. Epub 2014 Oct 24.
3
Pulmonary vascular hemodynamic response to exercise in cardiopulmonary diseases.
Circulation. 2013 Sep 24;128(13):1470-9. doi: 10.1161/CIRCULATIONAHA.112.000667.
4
Continuous non-invasive cardiac output measurements in the neonate by electrical velocimetry: a comparison with echocardiography.
Arch Dis Child Fetal Neonatal Ed. 2012 Sep;97(5):F340-3. doi: 10.1136/fetalneonatal-2011-301090.
5
Thermodilution and Fick cardiac outputs differ: impact on pulmonary hypertension evaluation.
Can Respir J. 2012 Jul-Aug;19(4):261-6. doi: 10.1155/2012/261793.
6
Exercise oscillatory ventilation in systolic heart failure: an indicator of impaired hemodynamic response to exercise.
Circulation. 2011 Sep 27;124(13):1442-51. doi: 10.1161/CIRCULATIONAHA.111.024141. Epub 2011 Aug 29.
7
Lack of agreement between thermodilution and fick methods in the measurement of cardiac output.
J Intensive Care Med. 2006 Mar-Apr;21(2):93-8. doi: 10.1177/0885066605285234.
8
Stroke volume equation for impedance cardiography.
Med Biol Eng Comput. 2005 Jul;43(4):443-50. doi: 10.1007/BF02344724.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验