The aim of this study is to evaluate performance of Matching Pursuit (MP) algorithm against visual analysis for automatic sleep spindle (SS) detection in a sample of sleep stages 2-4 and REM pertaining to nine healthy young subjects. MP-SS voltage, frequency and duration characteristics were investigated for the amplitude threshold (AT) that maximized yield between test sensitivity and specificity. Parameter distribution curves were also built for correctly detected (true positive) and false-positive events. For sleep stage 2, MP reached 80.6% sensitivity and specificity for an AT value of 58.8. For all stages together, 81.2% sensitivity and specificity were reached for an AT value of 46.6. Specificity curves were adequate for all stages; sensitivity was lower for S3+4. Sigma frequency range activity with atypical characteristics was detected within REM sleep. Prevalence indexes obtained with MP were much higher than visual prevalence indexes for all stages; similar voltage, frequency and duration distribution curves were obtained for true positive and false positive events. For this sample of young male healthy subjects, the free-ware MP algorithm showed satisfactory performance for SS detection in sleep stage 2 as reported earlier, acceptable performance in sleep stages 3+4, although with lowered sensitivity, and sigma frequency range activity within REM sleep that needs better understanding. Within NREM sleep, correspondence between the MP automatic and the visual method was supported.
本研究的目的是在9名健康年轻受试者的2-4期睡眠阶段和快速眼动(REM)睡眠样本中,评估匹配追踪(MP)算法相对于视觉分析自动检测睡眠纺锤波(SS)的性能。针对在测试敏感性和特异性之间实现最大产出的幅度阈值(AT),研究了MP-SS的电压、频率和持续时间特征。还针对正确检测到的(真阳性)事件和假阳性事件绘制了参数分布曲线。对于睡眠阶段2,当AT值为58.8时,MP的敏感性和特异性达到80.6%。对于所有阶段,当AT值为46.6时,敏感性和特异性达到81.2%。所有阶段的特异性曲线都合适;S3+4阶段的敏感性较低。在REM睡眠中检测到具有非典型特征的西格玛频率范围活动。MP获得的患病率指数远高于所有阶段的视觉患病率指数;真阳性和假阳性事件获得了相似的电压、频率和持续时间分布曲线。对于这个年轻男性健康受试者样本,免费的MP算法在睡眠阶段2的SS检测中表现出如先前报道的令人满意的性能,在睡眠阶段3+4表现出可接受的性能,尽管敏感性有所降低,并且在REM睡眠中有西格玛频率范围活动,这需要更好地理解。在非快速眼动睡眠中,支持MP自动检测方法与视觉方法之间的一致性。