Department of Botany, University of Georgia, Athens, Georgia 30601.
Plant Physiol. 1980 Jun;65(6):1133-5. doi: 10.1104/pp.65.6.1133.
Turgor pressure in individual sieve tubes was measured directly by gluing capillary micromanometers over exuding aphid stylets with cyanoac-rylate adhesive. Pressures of up to 10 bars were measured in sieve tubes of Salix babylonica, with an estimated accuracy of +/- 0.3 bars or better.For comparison with the direct measurements of sieve tube turgor, calculated values of turgor pressure were also obtained from the difference between leaf water potential and phloem exudate solute potential, estimated from its refractive index and sucrose content. In most cases the measured turgor pressure was greater than the calculated value. The discrepancy between the two values was most likely due to the presence of appreciable concentrations of potassium and amino acids in the phloem exudate.
用氰基丙烯酸酯将毛细管微压计粘在渗出的蚜虫口针上,直接测量单个筛管的膨压。用这种方法测量了柳属植物筛管中的压力,最高可达 10 巴,估计精度在 +/- 0.3 巴或更好。为了与筛管膨压的直接测量值进行比较,还根据其折射率和蔗糖含量,从叶片水势和韧皮部渗出液溶质势的差值计算得到了膨压值。在大多数情况下,测量的膨压大于计算值。这两个值之间的差异很可能是由于韧皮部渗出物中存在可观浓度的钾和氨基酸。