Suppr超能文献

计算机断层血管造影术体外测量血管壁衰减的准确性:壁厚度、造影剂密度和测量点的影响

Accuracy of attenuation measurement of vascular wall in vitro on computed tomography angiography: Effect of wall thickness, density of contrast medium, and measurement point.

作者信息

Suzuki Shigeru, Furui Shigeru, Kuwahara Sadatoshi, Kaminaga Tatsuro, Yamauchi Teiyu, Konno Kumiko, Yokoyama Naoyuki, Isshiki Takaaki

机构信息

Department of Radiology, Teikyo University School of Medicine, Tokyo, Japan.

出版信息

Invest Radiol. 2006 Jun;41(6):510-5. doi: 10.1097/01.rli.0000209662.24569.c7.

Abstract

OBJECTIVES

We sought to assess the effects of measurement point, wall thickness, and intravascular density of contrast material on attenuation measurement of vascular wall.

MATERIALS AND METHODS

We used vascular models (actual attenuation value of the wall: 83 HU) with wall thicknesses of 1.5, 1.0, or 0.5 mm, filled with contrast material of 254, 325, or 400 HU. The 9 vascular models were fixed in an oil-filled container and scanned with a 16-detector computed tomography. The wall attenuation values were measured at 1 point for 0.5-mm thickness models, 3 for 1.0-mm thickness models, and 5 for 1.5-mm thickness models with the same interval of 0.25 mm. Total 20 measurements were done for each point.

RESULTS

For 1.0-mm and 1.5-mm thickness models, wall attenuation progressively increased as the measurement points approached the lumen (P < 0.0001). At all the measurement points for 0.5-mm and 1.0-mm thickness models and the 2 inner measurement points for 1.5-mm thickness models, the densities of contrast material affected the wall attenuations significantly (P < 0.0001). At the midportion for 1.5-mm thickness models, the wall attenuations were not affected by the densities of the contrast material (P = 0.6301), and were 65-68 HU.

CONCLUSIONS

The effects of the intravascular density of contrast material, measurement point, and wall thickness should be considered in the attenuation measurement of the wall.

摘要

目的

我们试图评估测量点、壁厚及造影剂血管内密度对血管壁衰减测量的影响。

材料与方法

我们使用壁厚分别为1.5毫米、1.0毫米或0.5毫米的血管模型(血管壁实际衰减值:83HU),并填充254HU、325HU或400HU的造影剂。将9个血管模型固定于充满油的容器中,并用16排计算机断层扫描进行扫描。对于0.5毫米厚的模型,在1个点测量血管壁衰减值;对于1.0毫米厚的模型,在3个点测量;对于1.5毫米厚的模型,在5个点测量,测量间隔均为0.25毫米。每个点总共进行20次测量。

结果

对于1.0毫米和1.5毫米厚的模型,随着测量点靠近管腔,血管壁衰减逐渐增加(P<0.0001)。对于0.5毫米和1.0毫米厚的模型的所有测量点以及1.5毫米厚的模型的2个内侧测量点,造影剂密度对血管壁衰减有显著影响(P<0.0001)。对于1.5毫米厚的模型的中间部分,血管壁衰减不受造影剂密度影响(P = 0.6301),衰减值为65 - 68HU。

结论

在血管壁衰减测量中应考虑造影剂血管内密度、测量点及壁厚的影响。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验