Suppr超能文献

技术见解:用于食管动力测试的联合阻抗测压法——当前结果及进一步影响

Technological insights: combined impedance manometry for esophageal motility testing-current results and further implications.

作者信息

Nguyen Huan Nam, Domingues Gerson Ricardo Souza, Lammert Frank

机构信息

Department of Internal Medicine, University of Technology RWTH-Aachen, Germany.

出版信息

World J Gastroenterol. 2006 Oct 21;12(39):6266-73. doi: 10.3748/wjg.v12.i39.6266.

Abstract

This review focuses on current aspects of the novel technology of combined impedance manometry for esophageal motility testing. It presents methodological features, summarizes current results and discusses implications for further research. The combined technique assesses simultaneously bolus transport and associated peristalsis, thus allowing detailed analysis of the relationships between bolus transit and esophageal motility. Recent studies demonstrate that combined impedance manometry provides important additional information about esophageal motility as compared to conventional manometry: (1) monitoring of bolus transport patterns, (2) calculation of bolus transit parameters, (3) evaluation of bolus clearance, (4) monitoring of swallow associated events such as air movement and reflux, and (5) investigation of the relationships between bolus transit and LES relaxation. Studies with healthy subjects have identified several useful parameters for comprehensive assessment of eosphageal function. These parameters were found to be pathological in patients with classical achalasia, mild GERD, and ineffective esophageal motility. The technology of combined impedance manometry provides an important new tool for esophageal function testing, advancing both clinical and basic research. However, several important issues remain to be standardized to make the technique suitable for widely clinical use.

摘要

本综述聚焦于用于食管动力测试的联合阻抗测压新技术的当前各个方面。它介绍了方法学特点,总结了当前结果,并讨论了对进一步研究的意义。联合技术可同时评估食团传输及相关蠕动,从而能够对食团通过与食管动力之间的关系进行详细分析。近期研究表明,与传统测压相比,联合阻抗测压可提供有关食管动力的重要额外信息:(1)监测食团传输模式,(2)计算食团通过参数,(3)评估食团清除情况,(4)监测吞咽相关事件,如空气流动和反流,以及(5)研究食团通过与LES松弛之间的关系。对健康受试者的研究已确定了几个用于全面评估食管功能的有用参数。在经典失弛缓症、轻度胃食管反流病和无效食管动力患者中,这些参数被发现存在病理改变。联合阻抗测压技术为食管功能测试提供了一个重要的新工具,推动了临床和基础研究的发展。然而,仍有几个重要问题有待规范,以使该技术适合广泛的临床应用。

相似文献

4
Combined multichannel intraluminal impedance and manometry testing.联合多通道腔内阻抗和测压测试
Dig Liver Dis. 2008 Mar;40(3):167-73. doi: 10.1016/j.dld.2007.11.007. Epub 2008 Jan 4.
10
Technology review: Esophageal impedance monitoring.技术综述:食管阻抗监测
Am J Gastroenterol. 2007 Jan;102(1):187-94. doi: 10.1111/j.1572-0241.2006.00966.x. Epub 2006 Nov 13.

引用本文的文献

5
Manometry data support a novel concept of the lower esophageal sphincter system.测压数据支持食管下括约肌系统的新概念。
Langenbecks Arch Surg. 2010 Nov;395(8):1083-91. doi: 10.1007/s00423-010-0662-x. Epub 2010 Jul 8.

本文引用的文献

3
Characteristics of oesophageal bolus transport in patients with mild oesophagitis.轻度食管炎患者食管团块运输的特征
Eur J Gastroenterol Hepatol. 2005 Mar;17(3):323-32. doi: 10.1097/00042737-200503000-00011.
9
Impedance characteristics of normal oesophageal motor function.正常食管运动功能的阻抗特征
Eur J Gastroenterol Hepatol. 2003 Jul;15(7):773-80. doi: 10.1097/01.meg.0000059161.46867.2b.