An evaluation of the physical and functional characteristics of resuscitators for use in pediatrics.

作者信息

Kissoon N, Connors R, Tiffin N, Frewen T C

机构信息

Department of Pediatric Emergency and Critical Care, Children's Hospital of Western Ontario, London, Canada.

出版信息

Crit Care Med. 1992 Feb;20(2):292-6. doi: 10.1097/00003246-199202000-00017.

DOI:10.1097/00003246-199202000-00017
PMID:1737462
Abstract

OBJECTIVE

To evaluate the physical and functional characteristics of pediatric self-inflating resuscitators.

DESIGN

Tested under simulated clinical conditions. Results were analyzed by descriptive analysis.

SETTING

A pulmonary laboratory in a university hospital.

METHODS

Eight new pediatric self-inflating resuscitators were obtained from the manufacturers and evaluated for functional characteristics including: a) fraction of delivered oxygen at 10 L/min and a tidal volume of 300 mL; b) maximum stroke volume against no resistance; and c) maximum cycling frequency at -5 degrees C, 20 degrees C, and 48 degrees C. The resuscitators were also evaluated for physical characteristics, including potential for misassembly, pressure relief valves, expiratory valve leak, and inspiratory resistance.

RESULTS

All resuscitators met the minimum standards of the Canadian Standards Association and American Standards for Testing of Materials. However, one bag cycled at only 32 breaths/min at -5 degrees C, marginally within accepted standards. Only five self-inflating resuscitators had pop-off valves. These valves malfunctioned, with valve activation occurring well above the accepted standards. Three of the self-inflating resuscitators could be misassembled for use. Four of the resuscitators were unable to deliver tidal volumes required for preoxygenation in a 20-kg child.

CONCLUSIONS

While these self-inflating resuscitators met the minimum standards, they are all unable to deliver 100% oxygen. One unit is probably not appropriate in the out-of-hospital setting when ambient temperatures are less than 0 degrees C. Those resuscitators that can be misassembled are dangerous in unskilled hands. In addition, reliance on pop-off valve activation to limit airway pressure is dangerous.

摘要

相似文献

1
An evaluation of the physical and functional characteristics of resuscitators for use in pediatrics.
Crit Care Med. 1992 Feb;20(2):292-6. doi: 10.1097/00003246-199202000-00017.
2
Evaluation of performance characteristics of disposable bag-valve resuscitators.一次性袋-阀复苏器性能特征评估
Crit Care Med. 1991 Jan;19(1):102-7. doi: 10.1097/00003246-199101000-00022.
3
Pediatric self-inflating resuscitators: the dangers of improper setup.儿科自动充气式复苏器:设置不当的危险。
J Emerg Med. 2011 Dec;41(6):607-12. doi: 10.1016/j.jemermed.2009.04.038. Epub 2009 May 17.
4
An evaluation of the physical and functional characteristics of infant resuscitators.婴儿复苏器的物理和功能特性评估。
Pediatr Emerg Care. 1993 Apr;9(2):104-7. doi: 10.1097/00006565-199304000-00012.
5
Evaluation of ten manual resuscitators across an operational temperature range of -18 degrees C to 50 degrees C.在-18摄氏度至50摄氏度的工作温度范围内对十种手动复苏器进行评估。
Respir Care. 1991 Mar;36(3):161-72.
6
An evaluation of the resistance to flow through the patient valves of twelve adult manual resuscitators.对十二款成人手动复苏器的病人阀的流动阻力进行评估。
Respir Care. 1992 May;37(5):432-8.
7
Evaluation of 16 adult disposable manual resuscitators.16款成人一次性手动复苏器的评估
Respir Care. 2004 Dec;49(12):1509-14.
8
Artificial ventilation during transport: A randomized crossover study of manual resuscitators with comparison to mechanical ventilators in a simulation model.转运期间的人工通气:在模拟模型中对人工复苏器与机械通气机进行比较的随机交叉研究。
Paediatr Anaesth. 2018 Sep;28(9):788-794. doi: 10.1111/pan.13389.
9
Comparison of the FiO2 delivered by seven models of the self-inflating bag-mask system.
Rev Bras Anestesiol. 2009 Jan-Feb;59(1):21-7. doi: 10.1590/s0034-70942009000100004.
10
Limitations of self-inflating resuscitators.
Pediatrics. 1986 Mar;77(3):417-20.