• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Information contained in sensory nerve recordings made with intrafascicular electrodes.

作者信息

Goodall E V, Lefurge T M, Horch K W

机构信息

Department of Bioengineering, University of Utah, Salt Lake City 84112.

出版信息

IEEE Trans Biomed Eng. 1991 Sep;38(9):846-50. doi: 10.1109/10.83604.

DOI:10.1109/10.83604
PMID:1743732
Abstract

Multiunit recordings were made in anesthetized cats with chronically implanted intrafascicular electrodes over a period of six months. Neural signals recorded with these electrodes consisted of activity in sensory fibers innervating a variety of cutaneous mechanoreceptors. Mechanical stimuli were used to selectively activate individual nerve fibers, and the receptive field and receptor type were identified for each unit. Over a period of six months, there was a net shift in the recorded population, but the electrodes continued to provide a representative sample of the activity in the fascicle as a whole. The total number of units from which activity could be recorded remained roughly constant with time, and individual units persisted in the recordings for up to six months. These results indicate that intrafascicular electrodes could be used to sample information carried by individual somatosensory fibers on a long term basis.

摘要

相似文献

1
Information contained in sensory nerve recordings made with intrafascicular electrodes.
IEEE Trans Biomed Eng. 1991 Sep;38(9):846-50. doi: 10.1109/10.83604.
2
Longitudinal intrafascicular electrodes in collection and analysis of sensory signals of the peripheral nerve in a feline model.纵向束内电极在猫模型中收集和分析周围神经感觉信号的应用
Microsurgery. 2005;25(7):561-5. doi: 10.1002/micr.20159.
3
Selective stimulation of peripheral nerve fibers using dual intrafascicular electrodes.使用双束内电极选择性刺激外周神经纤维。
IEEE Trans Biomed Eng. 1993 May;40(5):492-4. doi: 10.1109/10.243412.
4
[Experimental study of biocompatibility of LIFEs in peripheral fascicles].[周围神经束中LIFEs生物相容性的实验研究]
Zhonghua Yi Xue Za Zhi. 2003 Dec 25;83(24):2152-7.
5
[The unit activity of C fibers recorded in the human cutaneous nerve and its relationship to pain].
Acta Neurol Belg. 1973 Jan-Feb;73(1):39-43.
6
Action potential classification with dual channel intrafascicular electrodes.
IEEE Trans Biomed Eng. 1994 Jul;41(7):609-16. doi: 10.1109/10.301727.
7
Comparative analysis of transverse intrafascicular multichannel, longitudinal intrafascicular and multipolar cuff electrodes for the selective stimulation of nerve fascicles.横切式多通道神经内电极、纵切式神经内电极和多极套袖电极在选择性神经束刺激中的对比分析。
J Neural Eng. 2011 Jun;8(3):036023. doi: 10.1088/1741-2560/8/3/036023. Epub 2011 May 11.
8
Effect of long-term implanted nerve cuff electrodes on the electrophysiological properties of human sensory nerves.长期植入式神经袖套电极对人感觉神经电生理特性的影响。
Artif Organs. 1997 Mar;21(3):207-9.
9
Recording and stimulating properties of chronically implanted longitudinal intrafascicular electrodes in peripheral fascicles in an animal model.动物模型中慢性植入外周束内纵向束内电极的记录和刺激特性
Microsurgery. 2008;28(3):203-9. doi: 10.1002/micr.20465.
10
[Perspectives of effect on new electrode technology with implantable motor prostheses for stimulating peripheral nerves].[植入式运动假体刺激周围神经的新电极技术的效果展望]
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi. 1999 Dec;16(4):506-10, 515.

引用本文的文献

1
Fascicle-selective kilohertz-frequency neural conduction block with longitudinal intrafascicular electrodes.采用纵向束内电极实现的束状选择性千赫兹频率神经传导阻滞。
J Neural Eng. 2025 Apr 4;22(2):026045. doi: 10.1088/1741-2552/adc62a.
2
Update on Peripheral Nerve Electrodes for Closed-Loop Neuroprosthetics.用于闭环神经假体的周围神经电极的最新进展
Front Neurosci. 2018 May 28;12:350. doi: 10.3389/fnins.2018.00350. eCollection 2018.
3
Bionic intrafascicular interfaces for recording and stimulating peripheral nerve fibers.用于记录和刺激外周神经纤维的仿生束内接口。
Bioelectron Med (Lond). 2018 Jan;1(1):55-69. doi: 10.2217/bem-2017-0009. Epub 2017 Dec 14.
4
On the viability of implantable electrodes for the natural control of artificial limbs: review and discussion.可植入电极用于自然控制义肢的可行性:综述与讨论。
Biomed Eng Online. 2012 Jun 20;11:33. doi: 10.1186/1475-925X-11-33.
5
Analysis of single-unit firing patterns in multi-unit intrafascicular recordings.多单元束内记录中单个神经元放电模式的分析。
Med Biol Eng Comput. 1993 May;31(3):257-67. doi: 10.1007/BF02458045.
6
Reduced fatigue in electrically stimulated muscle using dual channel intrafascicular electrodes with interleaved stimulation.使用具有交错刺激的双通道束内电极减轻电刺激肌肉中的疲劳。
Ann Biomed Eng. 1993 Nov-Dec;21(6):709-14. doi: 10.1007/BF02368649.
7
Chronically implanted intrafascicular recording electrodes.长期植入的束内记录电极。
Ann Biomed Eng. 1991;19(2):197-207. doi: 10.1007/BF02368469.