Yoshida K, Horch K
Dept. Bioengineering, University Utah, Salt Lake City 84112.
Ann Biomed Eng. 1993 Nov-Dec;21(6):709-14. doi: 10.1007/BF02368649.
Pairs of intrafascicular electrodes were implanted within single fascicles of the nerve innervating the gastrocnemius muscle in cats. Measurements were made of fatigue induced in the muscle by single and dual channel tetanic stimulation. The level and rate of fatigue induced by concurrent dual channel stimulation (pulses presented simultaneously to the two electrodes) did not differ significantly from that induced by single channel stimulation. However, a significant reduction in the level and rate of muscle fatigue was found with interleaved dual channel stimulation. The extent of reduction in fatigue was found to be inversely related to the amount of overlap in the axonal populations activated by each of the two electrodes.
将成对的束内电极植入猫的腓肠肌神经的单个束内。通过单通道和双通道强直刺激来测量肌肉中诱导产生的疲劳。同时进行双通道刺激(脉冲同时施加于两个电极)所诱导产生的疲劳程度和速率,与单通道刺激所诱导产生的并无显著差异。然而,交错式双通道刺激时,肌肉疲劳的程度和速率显著降低。研究发现,疲劳降低的程度与两个电极各自激活的轴突群体中的重叠量呈负相关。