Tseng Santos Shan-Yu, Hsiao John Ching-Jen, Chang David Chao-Kai
Department of Optometry, Chung Shan Medical University, Taichung, Taiwan.
Cornea. 2007 Oct;26(9):1153-5. doi: 10.1097/ICO.0b013e318055e65c.
We report a case of corneal warpage secondary to hydrogel lens wear that was initially mistaken as a case of keratoconus.
A 26-year-old Chinese female hydrogel lens wearer presented with an interest in refractive surgery. After topographies and pachymetries were performed, keratoconus was initially diagnosed for her right eye and suspect keratoconus diagnosed for her left eye. This conclusion was felt to be confirmed at a follow-up visit 1 week later, but keratoconus contact lens treatment was delayed because of the presence of superficial punctate keratitis.
After 8 weeks without lens wear, corneal maps were performed again. The maps now showed regular with-the-rule astigmatism, and none of the previous evidence of keratoconus. Central pachymetries were also normal.
Soft contact lens wear can induce corneal warpage mimicking keratoconus. Had the standard treatment for keratoconus been implemented before resolution of the warpage, it could have proven injurious to the patient, because the treatment itself could have provided an impetus for the protrusion to remain or perhaps even progress. Our case gives clinicians reason to pause when dealing with contact lens wearers presenting with corneal curvature irregularities such as keratoconus or ectasia, because of the possibility of lens-induced warpage.
我们报告一例因佩戴水凝胶镜片继发角膜变形的病例,该病例最初被误诊为圆锥角膜。
一名26岁佩戴水凝胶镜片的中国女性对屈光手术感兴趣。在进行角膜地形图和角膜厚度测量后,最初诊断其右眼为圆锥角膜,左眼为疑似圆锥角膜。一周后的随访检查似乎证实了这一诊断,但由于存在浅层点状角膜炎,圆锥角膜隐形眼镜治疗被推迟。
在停止佩戴镜片8周后,再次进行角膜地形图检查。地形图显示为规则的顺规散光,之前圆锥角膜的迹象均消失。中央角膜厚度测量也正常。
软性隐形眼镜佩戴可导致角膜变形,酷似圆锥角膜。如果在角膜变形消除之前就实施圆锥角膜的标准治疗,可能会对患者造成伤害,因为治疗本身可能会促使角膜突出持续存在甚至进展。我们的病例提示临床医生,在处理出现角膜曲率不规则(如圆锥角膜或角膜扩张)的隐形眼镜佩戴者时应谨慎,因为存在镜片诱导角膜变形的可能性。