两种不同根尖定位仪在有无牙根吸收的乳磨牙中的准确性。

Accuracy of two different apex locators in primary teeth with and without root resorption.

作者信息

Bodur Haluk, Odabaş Mesut, Tulunoğlu Ozlem, Tinaz Ali Cemal

机构信息

Department of Pediatric Dentistry, University of Gazi Faculty of Dentistry, Emek, Ankara, Turkey.

出版信息

Clin Oral Investig. 2008 Jun;12(2):137-41. doi: 10.1007/s00784-007-0157-5. Epub 2007 Nov 20.

Abstract

The objective of this study was to assess the accuracy of two frequency apex locators, Root ZX (Morita, Kyoto, Japan) and Endex (Osada, Tokyo, Japan) in primary teeth with and without root resorption in vitro. For this study, 90 sound extracted primary teeth (60 molars and 30 incisors; 93 roots with visible resorption and 51 roots without) were selected. A total of 144 root canals were included. After access preparation, root canal lengths were measured visually. The teeth were embedded in an alginate model developed specifically for testing apex locators. Electronic length was determined with two different frequency apex locators, Root ZX (Morita, Kyoto, Japan) and Endex (Osada, Tokyo, Japan). Statistical evaluation was performed using Mann-Whitney U and Wilcoxon W tests (p < 0.05). Results revealed that both apex locator devices did not show similar values to visual length measurements with statistically significant differences in primary teeth with root resorption (p < 0.05). For the teeth without root resorption, Endex showed similar values to visual length measurements with no statistically significant differences (p > 0.05), but Root ZX values were different than visual length and the differences were statistically significant (p < 0.05). There were no significant differences between the two apex locators considering the presence of root resorption. The two frequency apex locators can be recommended for use in root canal therapy for primary teeth with and without root resorption, only if electrical determination of root canal length is supported with other diagnostic measures.

摘要

本研究的目的是评估两种频率根尖定位仪,即日本京都森田公司生产的Root ZX和日本东京小田公司生产的Endex,在体外有无牙根吸收的乳牙髓腔治疗中的准确性。本研究选取了90颗完好的离体乳牙(60颗磨牙和30颗切牙;93个牙根有明显吸收,51个牙根无吸收),共纳入144个根管。开髓预备后,肉眼测量根管长度。将牙齿嵌入专门为测试根尖定位仪开发的藻酸盐模型中。使用两种不同频率的根尖定位仪,即日本京都森田公司生产的Root ZX和日本东京小田公司生产的Endex,测定电子长度。采用Mann-Whitney U检验和Wilcoxon W检验进行统计学评估(p<0.05)。结果显示,在有牙根吸收的乳牙中,两种根尖定位仪测得的值与肉眼测量长度均不相似,差异有统计学意义(p<0.05)。对于无牙根吸收的牙齿,Endex测得的值与肉眼测量长度相似,差异无统计学意义(p>0.05),但Root ZX测得的值与肉眼测量长度不同,差异有统计学意义(p<0.05)。考虑到牙根吸收情况,两种根尖定位仪之间无显著差异。只有在根管长度的电测定得到其他诊断措施支持的情况下,这两种频率的根尖定位仪才可推荐用于有无牙根吸收的乳牙根管治疗。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验