Canine left latissimus dorsi (LD) muscles were used to construct two kinds of skeletal muscle powered ventricles (SMPV): a double layered small size (10-17 mL) SMPV (A), and a single-layered large size (40-70 mL) SMPV (B). The same muscle was used sequentially for the construction of both SMPV. A mock circulation system was used for testing. This allowed for change of the preload (10-60 mmHg) and afterload (40-160 mmHg) independently. The peak developed pressure (PDP) and stroke volume (SV) were measured, and the stroke work (SW) was analyzed on line by a computer. The isovolumic PDP was 93.3 +/- 11.8 mmHg at 10 mmHg preload, and 157.7 +/- 20.2 mmHg at 60 mmHg for A, and 37.8 +/- 5.5 mHg and 107.8 +/- 8.5 mmHg for B. The SV and SW at 50 mmHg preload and 80 mmHg afterload were 18.30 +/- 1.25 mL and 1.06 +/- 0.10 x 10(6) erg for A, and 34.18 +/- 2.36 mL and 2.51 +/- 0.28 x 10(6) erg for B. The SV and SW at 20 mmHg preload and 160 mmHg afterload were 2.65 +/- 0.31 mL and 0.27 +/- 0.05 x 10(6) erg for A, and 1.03 +/- 0.23 mL and 0.04 +/- 0.01 x 10(6) erg for (B). The SW generated by the large single-layered SMPV is similar to that reported for the canine left ventricle but requires a high preload. The large single-layered SMPV showed a higher dependence on pre- and afterload changes than the double layered small SMPV, which generates a higher pressure even at low preloads.

摘要

犬类的左背阔肌(LD)被用于构建两种骨骼肌动力心室(SMPV):双层小尺寸(10 - 17毫升)的SMPV(A)和单层大尺寸(40 - 70毫升)的SMPV(B)。同一块肌肉被依次用于构建这两种SMPV。使用模拟循环系统进行测试。这使得能够独立改变前负荷(10 - 60毫米汞柱)和后负荷(40 - 160毫米汞柱)。测量了峰值收缩压(PDP)和每搏输出量(SV),并通过计算机在线分析每搏功(SW)。对于A,在10毫米汞柱前负荷时等容PDP为93.3±11.8毫米汞柱,在60毫米汞柱时为157.7±20.2毫米汞柱;对于B,分别为37.8±5.5毫米汞柱和107.8±8.5毫米汞柱。在50毫米汞柱前负荷和80毫米汞柱后负荷下,A的SV和SW分别为18.30±1.25毫升和1.06±0.10×10⁶尔格,B的分别为34.18±2.36毫升和2.51±0.28×10⁶尔格。在20毫米汞柱前负荷和160毫米汞柱后负荷下,A的SV和SW分别为2.65±0.31毫升和0.27±0.05×10⁶尔格,B的分别为1.03±0.23毫升和0.04±0.01×10⁶尔格。单层大尺寸SMPV产生的每搏功与犬类左心室报道的相似,但需要较高的前负荷。单层大尺寸SMPV对前负荷和后负荷变化的依赖性高于双层小尺寸SMPV,双层小尺寸SMPV即使在低前负荷下也能产生较高的压力。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验