Bragdon Charles R, Kwon Young Min, Geller Jeffrey A, Greene Meridith E, Freiberg Andrew A, Harris William H, Malchau Henrik
The Harris Orthopaedic Biomechanics & Biomaterials Laboratory, Massachusetts General Hospital, Boston, MA 02114, USA.
Clin Orthop Relat Res. 2007 Dec;465:122-7. doi: 10.1097/BLO.0b013e31815760b1.
To reduce wear rates and particulate debris, highly cross-linked polyethylene has been in use in total hip arthroplasty for 8 years. We designed this followup study to primarily determine the total penetration rate of the femoral head and the steady-state wear rate of cross-linked polyethylene in patients undergoing primary total hip arthroplasty. We retrospectively reviewed data from 182 patients (200 hips) with a minimum 6-year followup (mean, 6.9 years; range, 6-8 years) and an average age of 60.2 years at surgery. The average Harris hip score, University of California-Los Angeles activity score, and WOMAC score were 91.1, 6.3, and 11.3, respectively. Radiographic evaluation showed no evidence of loosening or osteolytic lesions around the cup or stem. No revisions were performed for polyethylene wear or liner fracture. The average steady-state wear rate was -0.002 +/- 0.01 mm per year and -0.026 +/- 0.13 mm per year for 28-mm and 32-mm head sizes, respectively. We observed no correlation between the total wear rate and femoral head size, brand of polyethylene, age, gender, primary diagnosis, mode of fixation, surgical approach, University of California-Los Angeles activity score, Harris hip score, or WOMAC. Highly cross-linked polyethylene liners are associated with excellent midterm clinical, radiographic, and wear results in this group of patients.
为降低磨损率和颗粒碎屑,高交联聚乙烯已在全髋关节置换术中应用了8年。我们设计了这项随访研究,主要目的是确定初次全髋关节置换术患者中股骨头的总穿透率以及交联聚乙烯的稳态磨损率。我们回顾性分析了182例患者(200髋)的数据,这些患者至少随访了6年(平均6.9年;范围6 - 8年),手术时平均年龄为60.2岁。平均Harris髋关节评分、加利福尼亚大学洛杉矶分校活动评分和WOMAC评分分别为91.1、6.3和11.3。影像学评估显示髋臼杯或股骨柄周围无松动或骨溶解病变迹象。未因聚乙烯磨损或衬垫骨折而进行翻修手术。对于28毫米和32毫米的股骨头尺寸,平均稳态磨损率分别为每年-0.002±0.01毫米和每年-0.026±0.13毫米。我们未观察到总磨损率与股骨头尺寸、聚乙烯品牌、年龄、性别、原发性诊断、固定方式、手术入路、加利福尼亚大学洛杉矶分校活动评分、Harris髋关节评分或WOMAC之间存在相关性。在这组患者中,高交联聚乙烯衬垫具有出色的中期临床、影像学和磨损结果。