Suppr超能文献

[罗伯特·科赫研究所软性内镜再处理指南的五年。回顾与展望]

[Five years of the Robert Koch Institute guidelines for reprocessing of flexible endoscopes. A look back and a look forward].

作者信息

Leiss O, Bader L, Mielke M, Exner M

机构信息

Gastroenterologische Gemeinschaftspraxis, Bahnhofplatz 2, Mainz, BRD.

出版信息

Bundesgesundheitsblatt Gesundheitsforschung Gesundheitsschutz. 2008 Feb;51(2):211-20. doi: 10.1007/s00103-008-0451-7.

Abstract

In a short review the national and international reception of the German guidelines for reprocessing flexible endoscopes is presented. The recommendations of the guidelines are discussed in view of recent knowledge on old problems such as prion inactivation and new infectious diseases and new microorganisms such as SARS, avian influenza and C. difficile. New disinfectants and new methods for endoscope disinfection are mentioned, the importance of careful cleaning is underlined. The German guidelines of the Robert Koch Institute and the US Multi-Society guidelines, published in 2003, are compared. The discrepancies concerning recommendations for water quality for final rinsing and need of microbiological controls of endoscope reprocessing are stressed. Aspects not mentioned in the German guidelines, e.g. duration of storage after reprocessing and risk of infection transmission by the endo-washer, are discussed.

摘要

本文简要回顾了德国软性内镜再处理指南在国内和国际上的接受情况。鉴于诸如朊病毒灭活等旧问题以及新型传染病和新型微生物(如非典、禽流感和艰难梭菌)的最新知识,对该指南的建议进行了讨论。文中提到了新型消毒剂和内镜消毒的新方法,强调了仔细清洁的重要性。对德国罗伯特·科赫研究所的指南和2003年发布的美国多学会指南进行了比较。强调了在最终冲洗水质建议以及内镜再处理微生物控制必要性方面存在的差异。还讨论了德国指南中未提及的方面,例如再处理后的储存时间以及内镜清洗机感染传播风险。

相似文献

1
[Five years of the Robert Koch Institute guidelines for reprocessing of flexible endoscopes. A look back and a look forward].
Bundesgesundheitsblatt Gesundheitsforschung Gesundheitsschutz. 2008 Feb;51(2):211-20. doi: 10.1007/s00103-008-0451-7.
3
Reprocessing endoscopes: national recommendations with a special emphasis on cleaning--the German perspective.
J Hosp Infect. 2004 Apr;56 Suppl 2:S23-6. doi: 10.1016/j.jhin.2003.12.034.
4
Reprocessing endoscopes: United States perspective.
J Hosp Infect. 2004 Apr;56 Suppl 2:S27-39. doi: 10.1016/j.jhin.2003.12.035.
5
Inconsistencies in endoscope-reprocessing and infection-control guidelines: the importance of endoscope drying.
Am J Gastroenterol. 2006 Sep;101(9):2147-54. doi: 10.1111/j.1572-0241.2006.00712.x.
8
Challenges in achieving effective high-level disinfection in endoscope reprocessing.
Am J Infect Control. 2020 Mar;48(3):309-315. doi: 10.1016/j.ajic.2019.09.013. Epub 2019 Oct 31.
9
Reprocessing of flexible endoscopes.
J Gastroenterol Hepatol. 2000 Oct;15 Suppl:G73-7. doi: 10.1046/j.1440-1746.2000.02269.x.
10
Reprocessing practices for gastrointestinal endoscopes: a multicentre study in Egyptian university hospitals.
East Mediterr Health J. 2017 Aug 27;23(7):514-519. doi: 10.26719/2017.23.7.514.

引用本文的文献

1
Is peracetic acid suitable for the cleaning step of reprocessing flexible endoscopes?
World J Gastrointest Endosc. 2014 Sep 16;6(9):390-406. doi: 10.4253/wjge.v6.i9.390.
3
Endowashers: an overlooked risk for possible post-endoscopic infections.
GMS Krankenhhyg Interdiszip. 2011;6(1):Doc13. doi: 10.3205/dgkh000170. Epub 2011 Dec 15.

本文引用的文献

2
Clinical review: update of avian influenza A infections in humans.
Crit Care. 2007;11(2):209. doi: 10.1186/cc5675.
4
Current status of screening colonoscopy in Europe and in the United States.
Endoscopy. 2007 Feb;39(2):168-73. doi: 10.1055/s-2007-966182.
5
Update on Clostridium difficile associated disease.
Curr Opin Gastroenterol. 2007 Jan;23(1):4-9. doi: 10.1097/MOG.0b013e32801184ac.
6
A new peroxide-based flexible endoscope-compatible high-level disinfectant.
Am J Infect Control. 2006 Nov;34(9):571-7. doi: 10.1016/j.ajic.2006.02.003.
7
Automated washing with the Reliance Endoscope Processing System and its equivalence to optimal manual cleaning.
Am J Infect Control. 2006 Nov;34(9):561-70. doi: 10.1016/j.ajic.2006.01.010.
9
Inconsistencies in endoscope-reprocessing and infection-control guidelines: the importance of endoscope drying.
Am J Gastroenterol. 2006 Sep;101(9):2147-54. doi: 10.1111/j.1572-0241.2006.00712.x.
10
Using an efficient biofilm detaching agent: an essential step for the improvement of endoscope reprocessing protocols.
J Hosp Infect. 2006 Oct;64(2):136-42. doi: 10.1016/j.jhin.2006.06.011. Epub 2006 Aug 21.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验