Suppr超能文献

阿肯色州启智中心教室中的空气过敏原暴露情况。

Classroom aeroallergen exposure in Arkansas head start centers.

作者信息

Perry Tamara T, Vargas Perla A, Bufford Jeremy, Feild Charles, Flick Michael, Simpson Pippa M, Hamilton Robert G, Jones Stacie M

机构信息

Department of Pediatrics, University of Arkansas for Medical Sciences, Arkansas Children's Hospital Research Institute, Little Rock, Arkansas 72202, USA.

出版信息

Ann Allergy Asthma Immunol. 2008 Apr;100(4):358-63. doi: 10.1016/S1081-1206(10)60599-6.

Abstract

BACKGROUND

The impact of preschool environmental conditions on classroom aeroallergen concentrations is not fully understood.

OBJECTIVE

To examine the relationship between school environmental conditions and classroom aeroallergen concentrations in the Pulaski County Head Start (HS) Program.

METHODS

Thirty-three HS centers in Pulaski County, Arkansas, underwent a detailed environmental evaluation. Classroom settled dust samples were analyzed for the presence of common indoor allergens.

RESULTS

Classroom eating (70%), wall-to-wall carpeting (58%), and water damage (33%) were common. Median classroom allergen levels were as follows: dust mite (Der p 1 and Der f 1), 0.6 microg/g; Fel d 1, 0.4 microg/g; Can f 1, 1.7 microg/g; cockroach, below detection; Mus m 1, 0.18 microg/g; and mold spores, 17,800 CFU/g. Can f 1 and Mus m 1 allergens were detected in 100% of HS centers. Facilities with carpeting, increased humidity, and single-use facilities showed trends toward increased dust mite concentrations. Detectable cockroach allergen was more common in classrooms cleaned by teachers than by professional housekeepers.

CONCLUSIONS

Aeroallergens were commonly detected in Pulaski County HS center classrooms, with dog and mouse allergens detected in 100% of centers. Median classroom allergen concentrations were low, and classroom characteristics were not strongly predictive of increased allergen exposure.

摘要

背景

学前环境条件对教室空气过敏原浓度的影响尚未完全明确。

目的

研究普拉斯基县启智计划(HS)中学校环境条件与教室空气过敏原浓度之间的关系。

方法

对阿肯色州普拉斯基县的33个HS中心进行了详细的环境评估。分析教室积尘样本中常见室内过敏原的存在情况。

结果

教室饮食(70%)、满铺地毯(58%)和水损(33%)情况较为常见。教室过敏原水平中位数如下:尘螨(Der p 1和Der f 1),0.6微克/克;猫过敏原(Fel d 1),0.4微克/克;狗过敏原(Can f 1),1.7微克/克;蟑螂过敏原,低于检测限;鼠过敏原(Mus m 1),0.18微克/克;霉菌孢子,17,800 CFU/克。100%的HS中心检测到Can f 1和Mus m 1过敏原。有地毯、湿度增加和一次性设施的场所,尘螨浓度有升高趋势。可检测到的蟑螂过敏原在由教师清洁的教室中比由专业保洁员清洁的教室中更常见。

结论

在普拉斯基县HS中心教室中普遍检测到空气过敏原,100%的中心检测到狗和鼠过敏原。教室过敏原浓度中位数较低,且教室特征对增加过敏原暴露的预测性不强。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验