Suppr超能文献

高度交联聚乙烯用于全膝关节置换术是安全的。

Highly crosslinked polyethylene is safe for use in total knee arthroplasty.

作者信息

Hodrick Jeffrey T, Severson Erik P, McAlister Deborah S, Dahl Brian, Hofmann Aaron A

机构信息

Southern Joint Replacement Institute, Nashville, TN 37205, USA.

出版信息

Clin Orthop Relat Res. 2008 Nov;466(11):2806-12. doi: 10.1007/s11999-008-0472-4. Epub 2008 Sep 10.

Abstract

UNLABELLED

Highly cross-linked polyethylene (XLPE) has been used with good initial success in hip arthroplasty to reduce wear. However, the process of crosslinking reduces fracture toughness, raising concerns as to whether it can be safely used in total knee arthroplasty (TKA). We therefore asked whether XLPE can be used safely in TKA. We performed a retrospective review of 100 subjects receiving XLPE and compared them to 100 subjects who received standard polyethylene in the setting of TKA. The standard polyethylene group had a mean age of 70 with a minimum follow up of 82 months. The highly cross-linked polyethylene group had a mean age of 67 and a minimum follow up of 69 months (mean, 75 months; range, 69-82 months). On radiographic review, the standard group demonstrated 20 TKAs with radiolucencies; 4 of these had evidence of a loose tibial component. The standard group required three revisions related to loose tibial components. The XLPE group had 2 subjects that demonstrated radiolucencies on radiograph and no subjects with evidence of tibial loosening. There were no reoperations related to osteolysis. The data suggest XLPE in TKA can be used safely at least short- to midterm. Our study provides an impetus for further long-term investigation.

LEVEL OF EVIDENCE

Level III, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.

摘要

未标注

高度交联聚乙烯(XLPE)已用于髋关节置换术并取得了良好的初期效果,以减少磨损。然而,交联过程会降低断裂韧性,这引发了人们对其能否安全用于全膝关节置换术(TKA)的担忧。因此,我们探讨了XLPE在TKA中能否安全使用。我们对100例接受XLPE的患者进行了回顾性研究,并将他们与100例在TKA中接受标准聚乙烯的患者进行比较。标准聚乙烯组的平均年龄为70岁,最短随访时间为82个月。高度交联聚乙烯组的平均年龄为67岁,最短随访时间为69个月(平均75个月;范围69 - 82个月)。经影像学检查,标准组有20例TKA出现透光线;其中4例有胫骨假体松动的证据。标准组有3例因胫骨假体松动需要翻修。XLPE组有2例在X线片上显示有透光线,但没有胫骨松动的证据。没有与骨溶解相关的再次手术。数据表明,XLPE在TKA中至少在短期至中期可以安全使用。我们的研究为进一步的长期研究提供了动力。

证据级别

III级,治疗性研究。有关证据级别的完整描述,请参阅作者指南。

相似文献

1
Highly crosslinked polyethylene is safe for use in total knee arthroplasty.
Clin Orthop Relat Res. 2008 Nov;466(11):2806-12. doi: 10.1007/s11999-008-0472-4. Epub 2008 Sep 10.
2
Highly Crosslinked-remelted versus Less-crosslinked Polyethylene in Posterior Cruciate-retaining TKAs in the Same Patients.
Clin Orthop Relat Res. 2015 Nov;473(11):3588-94. doi: 10.1007/s11999-015-4425-4. Epub 2015 Jun 27.
3
Surface Damage Is Not Reduced With Highly Crosslinked Polyethylene Tibial Inserts at Short-term.
Clin Orthop Relat Res. 2016 Jan;474(1):107-16. doi: 10.1007/s11999-015-4344-4.
7
Highly Cross-Linked Versus Conventional Polyethylene in Posterior-Stabilized Total Knee Arthroplasty at a Mean 5-Year Follow-up.
J Arthroplasty. 2015 Oct;30(10):1736-9. doi: 10.1016/j.arth.2015.05.009. Epub 2015 May 12.
8
Antioxidant-stabilized highly crosslinked polyethylene in total knee arthroplasty: a retrieval analysis.
Bone Joint J. 2018 Oct;100-B(10):1330-1335. doi: 10.1302/0301-620X.100B10.BJJ-2018-0061.R2.
9
Is Cross-Linked Polyethylene an Improvement Over Conventional Ultra-High Molecular Weight Polyethylene in Total Knee Arthroplasty?
J Arthroplasty. 2018 Mar;33(3):908-914. doi: 10.1016/j.arth.2017.10.005. Epub 2017 Oct 10.
10
Current Total Knee Designs: Does Baseplate Roughness or Locking Mechanism Design Affect Polyethylene Backside Wear?
Clin Orthop Relat Res. 2017 Dec;475(12):2970-2980. doi: 10.1007/s11999-017-5494-3. Epub 2017 Sep 13.

引用本文的文献

5
Cruciate Substituting Implants in Primary Total Knee Arthroplasty.
Adv Orthop. 2022 Jan 24;2022:2676715. doi: 10.1155/2022/2676715. eCollection 2022.
6
Massive Osteolysis in a Modern Total Knee Prosthesis.
Case Rep Orthop. 2021 Oct 20;2021:5507932. doi: 10.1155/2021/5507932. eCollection 2021.
8
Early failure of sequentially annealed polyethylene in total knee arthroplasty.
Arthroplast Today. 2020 Jan 9;6(1):18-22. doi: 10.1016/j.artd.2019.12.005. eCollection 2020 Mar.
10
Particle Disease: A Current Review of the Biological Mechanisms in Periprosthetic Osteolysis After Hip Arthroplasty.
Open Orthop J. 2016 Jul 15;10:241-51. doi: 10.2174/1874325001610010241. eCollection 2016.

本文引用的文献

1
Minimum 6-year followup of highly cross-linked polyethylene in THA.
Clin Orthop Relat Res. 2007 Dec;465:122-7. doi: 10.1097/BLO.0b013e31815760b1.
3
Simulated normal gait wear testing of a highly cross-linked polyethylene tibial insert.
J Arthroplasty. 2007 Apr;22(3):435-44. doi: 10.1016/j.arth.2006.07.014.
4
Wear and osteolysis around total knee arthroplasty.
J Am Acad Orthop Surg. 2007 Jan;15(1):53-64. doi: 10.5435/00124635-200701000-00006.
5
Oxidative degradation in highly cross-linked and conventional polyethylene after 2 years of real-time shelf aging.
Biomaterials. 2006 Apr;27(10):2275-84. doi: 10.1016/j.biomaterials.2005.11.010. Epub 2005 Nov 28.
6
Effect of cross-linking on the microstructure and mechanical properties of ultra-high molecular weight polyethylene.
Clin Orthop Relat Res. 2005 Nov;440:149-56. doi: 10.1097/01.blo.0000185310.59202.e5.
7
Polyethylene in knee arthroplasty: what is the future?
Clin Orthop Relat Res. 2005 Nov;440:141-8. doi: 10.1097/01.blo.0000187811.48717.9d.
8
Highly cross-linked polyethylene: the debate is over--in opposition.
J Arthroplasty. 2005 Jun;20(4 Suppl 2):59-62. doi: 10.1016/j.arth.2005.03.016.
9
Highly cross-linked polyethylene: the debate is over--in the affirmative.
J Arthroplasty. 2005 Jun;20(4 Suppl 2):55-8. doi: 10.1016/j.arth.2005.03.015.
10
Backside wear of polyethylene tibial inserts: mechanism and magnitude of material loss.
J Bone Joint Surg Am. 2005 Feb;87(2):326-31. doi: 10.2106/JBJS.C.01308.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验