Berglund I, Bengtsson E, Erikson U, Högman N, Nilsson S
Department of Diagnostic Radiology, Akademiska sjukhuset, Uppsala, Sweden.
Comput Methods Programs Biomed. 1991 May;35(1):1-10. doi: 10.1016/0169-2607(91)90098-e.
This report describes a method of quantifying the inner volume (lumen volume) of a contrast medium-filled femoral artery from a roentgenogram by computerized image analysis. The various factors influencing the accuracy of the volume determination are analyzed and an image-processing procedure for the elimination of artifacts due to crossing arteries is described and evaluated. The presented methods have been used in a large study of 281 patients and the short-term reproducibility has been found to be 1.00.