Hunt D A, Cartwright K A, Smith M C, Middleton J, Bartlett C L, Lee J V, Dennis P J, Harper D
Gloucester Health Authority.
Epidemiol Infect. 1991 Aug;107(1):133-41. doi: 10.1017/s0950268800048767.
Fourteen people living in or near the city of Gloucester fell ill with Legionnaires' disease caused by Legionella pneumophila serogroup (SG) 1 between 27 August and 27 October 1986. Another patient had fallen ill on 30 May. Nine of the 15 were diagnosed retrospectively during a case finding exercise. There were three deaths. Three cases of Pontiac fever were also diagnosed. The source was probably one or more wet cooling towers. Nineteen premises in the city with such towers were identified, and three just outside Gluocester. Samples from 11 of the 22 premises grew Legionella spp.; from nine of these L. pneumophila SG 1 (Pontiac) was isolated. The efficacy of regular addition of biocide in addition to hypochlorite added at the time of disinfection in inhibiting the growth of Legionella spp. was demonstrated. A survey of patients' movements during their likely incubation period showed that there was no single building that all patients had visited, but there were two areas of the city which nearly all had visited or passed through by car. A case-control study demonstrated an association with one of these areas. Cooling towers near both areas may have been sources but the evidence is insufficient to incriminate any single one. The unexpected finding of L. pneumophila SG 1 (Pontiac) in nine towers supports the hypothesis that there may have been multiple sources. Cooling towers may have been contaminated by mains water or by drift from other towers.
1986年8月27日至10月27日期间,居住在格洛斯特市或其附近的14人感染了由嗜肺军团菌血清群(SG)1引起的军团病。另一名患者于5月30日发病。在病例排查过程中,15名患者中有9名是回顾性诊断出来的。有3人死亡。还诊断出3例庞蒂亚克热病例。感染源可能是一个或多个湿式冷却塔。该市有19处带有此类冷却塔的场所被识别出来,格洛斯特市外还有3处。22处场所中有11处的样本培养出了军团菌属;其中9处分离出了嗜肺军团菌血清群1(庞蒂亚克型)。研究证明,除了在消毒时添加次氯酸盐外,定期添加杀生剂对抑制军团菌属生长具有效果。一项对患者在可能的潜伏期内活动情况的调查显示,没有一栋建筑物是所有患者都去过的,但该市有两个区域几乎所有患者都去过或乘车经过。一项病例对照研究表明与其中一个区域有关联。这两个区域附近的冷却塔都可能是感染源,但证据不足以认定任何一个冷却塔。在9个冷却塔中意外发现嗜肺军团菌血清群1(庞蒂亚克型),这支持了可能存在多个感染源的假设。冷却塔可能被市政供水或其他冷却塔的水滴污染。