Suppr超能文献

大头金属对金属非骨水泥型全髋关节置换术与28毫米金属对聚乙烯非骨水泥型全髋关节置换术:一项随机对照试验的设计

Large head metal-on-metal cementless total hip arthroplasty versus 28 mm metal-on-polyethylene cementless total hip arthroplasty: design of a randomized controlled trial.

作者信息

Zijlstra Wierd P, Bos Nanne, van Raaij Jos J A M

机构信息

Department of Orthopaedic Surgery, Martini Hospital, PO Box 30,033, 9700 RM Groningen, the Netherlands.

出版信息

BMC Musculoskelet Disord. 2008 Oct 8;9:136. doi: 10.1186/1471-2474-9-136.

Abstract

BACKGROUND

Osteoarthritis of the hip is successfully treated by total hip arthroplasty with metal-on-polyethylene articulation. Polyethylene wear debris can however lead to osteolysis, aseptic loosening and failure of the implant. Large head metal-on-metal total hip arthroplasty may overcome polyethylene wear induced prosthetic failure, but can increase systemic cobalt and chromium ion concentrations. The objective of this study is to compare two cementless total hip arthroplasties: a conventional 28 mm metal-on-polyethylene articulation and a large head metal-on-metal articulation. We hypothesize that the latter arthroplasties show less bone density loss and higher serum metal ion concentrations. We expect equal functional scores, greater range of motion, fewer dislocations, fewer periprosthetic radiolucencies and increased prosthetic survival with the metal-on-metal articulation.

METHODS

A randomized controlled trial will be conducted. Patients to be included suffer from non-inflammatory degenerative joint disease of the hip, are aged between 18 and 80 and are admitted for primary cementless unilateral total hip arthroplasty. Patients in the metal-on-metal group will receive a cementless titanium alloy acetabular component with a cobalt-chromium liner and a cobalt-chromium femoral head varying from 38 to 60 mm. Patients in the metal-on-polyethylene group will receive a cementless titanium alloy acetabular component with a polyethylene liner and a 28 mm cobalt-chromium femoral head. We will assess acetabular bone mineral density by dual energy x-ray absorptiometry (DEXA), serum ion concentrations of cobalt, chromium and titanium, self reported functional status (Oxford hip score), physician reported functional status and range of motion (Harris hip score), number of dislocations and prosthetic survival. Measurements will take place preoperatively, perioperatively, and postoperatively (6 weeks, 1 year, 5 years and 10 years).

DISCUSSION

Superior results of large head metal-on-metal total hip arthroplasty over conventional hip arthroplasty have been put forward by experts, case series and the industry, but to our knowledge there is no randomized controlled evidence.

CONCLUSION

This randomized controlled study has been designed to test whether large head metal-on-metal cementless total hip arthroplasty leads to less periprosthetic bone density loss and higher serum metal ion concentrations compared to 28 mm metal-on-polyethylene cementless total hip arthroplasty.

TRIAL REGISTRATION

Netherlands Trial Registry NTR1399.

摘要

背景

全髋关节置换术采用金属对聚乙烯关节面可成功治疗髋关节骨关节炎。然而,聚乙烯磨损颗粒可导致骨溶解、无菌性松动及植入物失效。大头金属对金属全髋关节置换术可能克服聚乙烯磨损所致的假体失效,但会增加全身钴和铬离子浓度。本研究的目的是比较两种非骨水泥型全髋关节置换术:传统的28毫米金属对聚乙烯关节面置换术和大头金属对金属关节面置换术。我们假设后一种关节置换术骨密度丢失更少且血清金属离子浓度更高。我们预期两种关节置换术功能评分相同、活动范围更大、脱位更少、假体周围透亮区更少且金属对金属关节面置换术假体生存率更高。

方法

将进行一项随机对照试验。纳入的患者患有髋关节非炎性退行性关节病,年龄在18至80岁之间,因初次非骨水泥型单侧全髋关节置换术入院。金属对金属组的患者将接受一个带钴铬内衬的非骨水泥型钛合金髋臼部件和一个直径从38至60毫米不等的钴铬股骨头。金属对聚乙烯组的患者将接受一个带聚乙烯内衬的非骨水泥型钛合金髋臼部件和一个28毫米钴铬股骨头。我们将通过双能X线吸收法(DEXA)评估髋臼骨矿物质密度、钴、铬和钛的血清离子浓度、自我报告的功能状态(牛津髋关节评分)、医生报告的功能状态和活动范围(哈里斯髋关节评分)、脱位次数及假体生存率。测量将在术前、围手术期及术后(6周、1年、5年和10年)进行。

讨论

专家、病例系列研究及业内人士均提出大头金属对金属全髋关节置换术优于传统髋关节置换术,但据我们所知,尚无随机对照证据。

结论

本随机对照研究旨在检验与28毫米金属对聚乙烯非骨水泥型全髋关节置换术相比,大头金属对金属非骨水泥型全髋关节置换术是否导致假体周围骨密度丢失更少且血清金属离子浓度更高。

试验注册

荷兰试验注册中心NTR1399 。

相似文献

6
Conus hip prosthesis.圆锥髋关节假体。
Acta Chir Orthop Traumatol Cech. 2001;68(4):213-21.

本文引用的文献

6
Metal-on-Metal total hip replacement: what does the literature say?
J Arthroplasty. 2005 Feb;20(2):174-88. doi: 10.1016/j.arth.2004.08.011.
7
A hip joint simulator study of the performance of metal-on-metal joints: Part II: design.
J Arthroplasty. 2004 Dec;19(8 Suppl 3):124-30. doi: 10.1016/j.arth.2004.09.016.

文献检索