Suppr超能文献

慢性卒中患者中StepWatch活动监测仪输出结果的重测信度

Test--retest reliability of the StepWatch Activity Monitor outputs in individuals with chronic stroke.

作者信息

Mudge Suzie, Stott N Susan

机构信息

Department of Surgery, University of Auckland, Auckland, New Zealand.

出版信息

Clin Rehabil. 2008 Oct-Nov;22(10-11):871-7. doi: 10.1177/0269215508092822.

Abstract

OBJECTIVE

To examine the test-retest reliability of the StepWatch Activity Monitor outputs over two periods, a week apart, in participants with stroke.

DESIGN

Test-retest reliability study over monitoring periods of one, two and three days.

SETTING

Participant's usual environment.

PARTICIPANTS

Forty participants more than six months post stroke.

MAIN MEASURES

StepWatch outputs: total step count, number of steps at high medium and low stepping rates, sustained activity indices, peak activity index.

RESULTS

The intraclass correlation coefficients were high for all StepWatch outputs and all monitoring periods but were highest for the three-day monitoring period (0.930-0.989) and lowest for the one-day monitoring period (0.830-0.950). The coefficient of variation ranged from 6.7% to 48.7% over the monitoring periods, with higher variation shown for shorter monitoring periods. The most reliable four outputs had 95% limits of agreement between three-day periods that were less than 40%. These were total step count (+/-37.8%), highest step rate in 1 minute (+/-23.0%), highest step rate in 5 minutes (+/-38.6%) and peak activity index (+/-29.8%). The highest step rate in 1 minute was the only StepWatch output that had 95% limits of agreement less than 40% for the two-day (+/-31.2%) and one-day (+/-36.7%) monitoring periods.

CONCLUSIONS

Total step count, highest step rate in 1 minute, highest step rate in 5 minutes and peak activity index have good test-retest reliability over a three-day monitoring period, with lower reliability shown by the other StepWatch outputs. In general, monitoring over one or two days is less reliable.

摘要

目的

研究中风患者在间隔一周的两个时间段内,StepWatch活动监测仪输出结果的重测信度。

设计

在1天、2天和3天的监测期内进行重测信度研究。

设置

参与者的日常环境。

参与者

40名中风后6个月以上的参与者。

主要测量指标

StepWatch输出结果:总步数、高、中、低步频的步数、持续活动指数、峰值活动指数。

结果

所有StepWatch输出结果在所有监测期内的组内相关系数都很高,但在3天监测期内最高(0.930 - 0.989),在1天监测期内最低(0.830 - 0.950)。在监测期内,变异系数在6.7%至48.7%之间,较短监测期的变异系数更高。最可靠的4项输出结果在3天时间段内的95%一致性界限小于40%。这些结果是总步数(±37.8%)、1分钟内最高步频(±23.0%)、5分钟内最高步频(±38.6%)和峰值活动指数(±29.8%)。1分钟内最高步频是唯一在2天(±31.2%)和1天(±36.7%)监测期内95%一致性界限小于40%的StepWatch输出结果。

结论

总步数、1分钟内最高步频、5分钟内最高步频和峰值活动指数在3天监测期内具有良好的重测信度,其他StepWatch输出结果的信度较低。一般来说,1天或2天的监测不太可靠。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验