Helbig Silke, Baumann Uwe, Helbig Matthias, von Malsen-Waldkirch Nicola, Gstoettner Wolfgang
ENT Department, Johann Wolfgang Goethe University, Frankfurt, Germany.
ORL J Otorhinolaryngol Relat Spec. 2008;70(6):359-65. doi: 10.1159/000163031. Epub 2008 Nov 4.
Electric acoustic stimulation (EAS) relies on the preservation of low-frequency hearing and adequate amplification of these frequencies. EAS has been achieved by fitting the cochlear implant (CI) speech processor together with an ipsilateral in-the-ear hearing aid. This study will evaluate the outcomes when CI/EAS users upgrade to a new combination of hearing aid and speech processor in 1 device (DUET).
Nine EAS patients participated in this study. Before switchover and after 2 and 8 months of DUET device use, they were assessed using monosyllables and sentences in quiet and in noise. Additionally, a questionnaire, the Abbreviated Profile for Hearing Aid Benefit (APHAB), was used to evaluate subjective impressions.
All subjects performed equally well, or even better, after switchover. This was also demonstrated over time. The participants with EAS before switchover performed equally afterwards, while those who used CI only did markedly better with the new device, especially in noisy conditions. Slight preference for the new system was also demonstrated with the APHAB.
All subjects showed benefit in noise; CI-only users before switchover particularly benefited from the new hearing system. Those who applied EAS before switchover performed equally well. The DUET allows individuals better access to EAS.
电声刺激(EAS)依赖于低频听力的保留以及这些频率的充分放大。通过将人工耳蜗(CI)言语处理器与同侧耳内助听器配合使用来实现EAS。本研究将评估CI/EAS使用者升级为一种设备(DUET)中的新型助听器和言语处理器组合后的效果。
9名EAS患者参与了本研究。在切换之前以及使用DUET设备2个月和8个月后,使用单音节词和句子在安静和噪声环境下对他们进行评估。此外,使用一份问卷,即《助听器效益简表》(APHAB)来评估主观感受。
所有受试者在切换后表现同样良好,甚至更好。随着时间推移这一点也得到了证明。切换前使用EAS的参与者之后表现相同,而那些之前仅使用CI的参与者使用新设备后明显表现更好,尤其是在噪声环境中。APHAB也显示出对新系统有轻微偏好。
所有受试者在噪声环境中均表现出获益;切换前仅使用CI的使用者尤其从新听力系统中获益。切换前应用EAS的使用者表现同样良好。DUET使个体能更好地使用EAS。