Suppr超能文献

氧化锆种植体的骨结合:骨-种植体界面的扫描电子显微镜观察

Osseointegration of zirconia implants: an SEM observation of the bone-implant interface.

作者信息

Depprich Rita, Zipprich Holger, Ommerborn Michelle, Mahn Eduardo, Lammers Lydia, Handschel Jörg, Naujoks Christian, Wiesmann Hans-Peter, Kübler Norbert R, Meyer Ulrich

机构信息

Department for Operative and Preventive Dentistry and Endodontics, Heinrich-Heine-University Duesseldorf, Germany.

出版信息

Head Face Med. 2008 Nov 6;4:25. doi: 10.1186/1746-160X-4-25.

Abstract

BACKGROUND

The successful use of zirconia ceramics in orthopedic surgery led to a demand for dental zirconium-based implant systems. Because of its excellent biomechanical characteristics, biocompatibility, and bright tooth-like color, zirconia (zirconium dioxide, ZrO2) has the potential to become a substitute for titanium as dental implant material. The present study aimed at investigating the osseointegration of zirconia implants with modified ablative surface at an ultrastructural level.

METHODS

A total of 24 zirconia implants with modified ablative surfaces and 24 titanium implants all of similar shape and surface structure were inserted into the tibia of 12 Göttinger minipigs. Block biopsies were harvested 1 week, 4 weeks or 12 weeks (four animals each) after surgery. Scanning electron microscopy (SEM) analysis was performed at the bone implant interface.

RESULTS

Remarkable bone attachment was already seen after 1 week which increased further to intimate bone contact after 4 weeks, observed on both zirconia and titanium implant surfaces. After 12 weeks, osseointegration without interposition of an interfacial layer was detected. At the ultrastructural level, there was no obvious difference between the osseointegration of zirconia implants with modified ablative surfaces and titanium implants with a similar surface topography.

CONCLUSION

The results of this study indicate similar osseointegration of zirconia and titanium implants at the ultrastructural level.

摘要

背景

氧化锆陶瓷在骨科手术中的成功应用引发了对牙科锆基种植系统的需求。由于其优异的生物力学特性、生物相容性以及类似牙齿的明亮色泽,氧化锆(二氧化锆,ZrO₂)有潜力成为牙科种植材料中钛的替代品。本研究旨在超微结构水平上研究具有改良消融表面的氧化锆种植体的骨结合情况。

方法

将总共24个具有改良消融表面的氧化锆种植体和24个形状及表面结构相似的钛种植体植入12只哥廷根小型猪的胫骨中。术后1周、4周或12周(每组4只动物)采集块状活检组织。在骨种植体界面进行扫描电子显微镜(SEM)分析。

结果

术后1周时,在氧化锆和钛种植体表面均已观察到明显的骨附着,4周后进一步增加至紧密的骨接触。12周后,检测到无界面层插入的骨结合。在超微结构水平上,具有改良消融表面的氧化锆种植体与表面形貌相似的钛种植体的骨结合情况无明显差异。

结论

本研究结果表明,在超微结构水平上,氧化锆种植体和钛种植体的骨结合情况相似。