RT-PCR法检测病毒病原体的四种鼻拭子采样方法比较——GA(2)LEN项目

Comparison of four nasal sampling methods for the detection of viral pathogens by RT-PCR-A GA(2)LEN project.

作者信息

Spyridaki Irini S, Christodoulou Ioannis, de Beer Lieke, Hovland Vegard, Kurowski Marcin, Olszewska-Ziaber Agnieszka, Carlsen Kai-Håkon, Lødrup-Carlsen Karin, van Drunen Cornelis M, Kowalski Marek L, Molenkamp Richard, Papadopoulos Nikolaos G

机构信息

Allergy Research Center, 2nd Pediatric Clinic, University of Athens, 41 Fidippidou str., 11527 Athens, Greece.

出版信息

J Virol Methods. 2009 Mar;156(1-2):102-6. doi: 10.1016/j.jviromet.2008.10.027. Epub 2008 Dec 19.

Abstract

The aim of this study was to compare the efficacy and patient discomfort between four techniques for obtaining nasal secretions. Nasal secretions from 58 patients with symptoms of a common cold, from three clinical centers (Amsterdam, Lodz, Oslo), were obtained by four different methods: swab, aspirate, brush, and wash. In each patient all four sampling procedures were performed and patient discomfort was evaluated by a visual discomfort scale (scale 1-5) after each procedure. Single pathogen RT-PCRs for Rhinovirus (RV), Influenza virus and Adenovirus, and multiplex real-time PCR for RV, Enterovirus, Influenza virus, Adenovirus, Respiratory Syncytial Virus (RSV), Parainfluenza virus, Coronavirus, Metapneumovirus, Bocavirus and Parechovirus were performed in all samples. A specific viral cause of respiratory tract infection was determined in 48 patients (83%). In these, the detection rate for any virus was 88% (wash), 79% (aspirate), 77% (swab) and 74% (brush). The degree of discomfort reported was 2.54 for swabs, 2.63 for washes, 2.68 for aspirates and 3.61 for brushings. Nasal washes yielded the highest rate of viral detection without excessive patient discomfort. In contrast, nasal brushes produced the lowest detection rates and demonstrated the highest level of discomfort.

摘要

本研究的目的是比较四种获取鼻分泌物技术的疗效和患者不适程度。来自三个临床中心(阿姆斯特丹、罗兹、奥斯陆)的58例有普通感冒症状的患者的鼻分泌物,通过四种不同方法获取:拭子、抽吸、刷取和冲洗。对每位患者均进行了所有四种采样程序,并在每个程序后通过视觉不适量表(1 - 5级)评估患者的不适程度。对所有样本进行了针对鼻病毒(RV)、流感病毒和腺病毒的单病原体逆转录聚合酶链反应(RT-PCR),以及针对RV、肠道病毒、流感病毒、腺病毒、呼吸道合胞病毒(RSV)、副流感病毒、冠状病毒、偏肺病毒、博卡病毒和帕里病毒的多重实时PCR。在48例患者(83%)中确定了呼吸道感染的特定病毒病因。其中,任何病毒的检出率分别为:冲洗88%、抽吸79%、拭子77%、刷取74%。报告的不适程度为:拭子2.54、冲洗2.63、抽吸2.68、刷取3.61。鼻腔冲洗产生的病毒检出率最高,且患者不适不过度。相比之下,鼻腔刷取的检出率最低,且不适程度最高。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/cfc6/7112903/29a7173e058c/gr1.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验